We present the multiscale entropy analysis of short term physiological time series of simultaneously acquired samples of heart rate, blood pressure and lung volume, from healthy subjects and from subjects with Chronic Heart Failure. Evaluating the complexity of signals at the multiple time scales inherent in physiologic dynamics, we find that healthy subjects show more complex time series at large time scales; on the other hand, at fast time scales, which are more influenced by respiration, the pathologic dynamics of blood pressure is the most random. These results robustly separate healthy and pathologic groups. We also propose a multiscale approach to evaluate interactions between time series, by performing a multivariate autoregressive modelling of the coarse grained time series: this analysis provides several new quantitative indicators which are statistically correlated with the pathology.
Heart and respiration rate measurement using Doppler radar is a non-contact and non-obstructive way for remote thorough-clothing monitoring of vital signs. The modulated back-scattered radar signal in the presence of high noise and interference is non-stationary with hidden periodicities, which cannot be detected by ordinary Fourier analysis. In this paper we propose a cyclostationary approach for such signals and show that by using non-linear transformation and then Fourier analysis of the radar signal, the hidden periodicities can be accurately obtained. Numerical results show that the vital…
Background --The objective of this study was to examine the association of routine blood test results with coronary heart disease (CHD) risk, to incorporate them into coronary prediction models and to compare the discrimination properties of this approach with other prediction functions. Methods and Results --This work was designed as a retrospective, single-center study of a hospital-based cohort. The 5060 CHD patients (2365 men and 2695 women) were 1 to 97 years old at baseline with 8 years (2009-2017) of medical records, 5051 health check-ups and 5075 cases of other diseases. We developed a…
Contact-free detection of human vital signs like heart rate and respiration rate will improve the patients' comfort and enables long-term monitoring of newborns or bedridden patients. For that, reliable and safe measurement techniques are indispensable. The aim of this work is the development and comparison of novel ultrasonic and capacitive measurement setups, sharing a common hardware platform. Both measurement techniques that are implemented and compared are based on the detection of minor chest wall vibrations in millimeter ranges, due to geometrical thorax changes during respiration and h…
This is a self-published methodological note distributed under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The note contains an original reasoning of mine and the goal to share thoughts and methodologies, not results. Therefore before using the contents of these notes, everyone is invited to verify the accuracy of the assumptions and conclusions.
The general public and medical professionals recognized the importance of accurately measuring and storing blood oxygen levels and heart rate during the COVID-19 pandemic. The demand for accurate contact-less devices was motivated by the need for cross-infection reduction and the shortage of conventional oximeters, partially due to the global supply chain issue. This paper evaluated a contact-less mini-program HealthyPai's heart rate (HR) and oxygen saturation (SpO2) measurements compared with other wearable devices. In the HR study of 185 samples (81 in the laboratory environment, 104 in the …
Differentiating patients with obstructive sleep apnea from healthy controls based on heart rate - blood pressure coupling quantified by entropy-based indices
Gdańsk University of Technology(格但斯克工业大学);Universidad Miguel Hernández(米格尔·埃尔南德斯大学);Medical University of Gdańsk(格但斯克医科大学)
Results of an experiment are presented whose aim is to explore the relationship between respiration and cerebral oxygenation. Measurements of end tidal CO2 (EtCO2) were taken simultaneously with cerebral oxygen saturation (rSO2) using the INVOS Cerebral Oximeter of Somanetics. Due to the device limitations we could explore only subjects who could perform with a breathing rate of around 2/min or less. Six subjects were used who were experienced in yoga breathing techniques. They performed an identical periodic breathing exercise including periodicity of about 2/min. The results of all six subje…
Background. Different mechanisms have been proposed to relate atrial fibrillation (AF) and coronary flow impairment, even in absence of relevant coronary artery disease (CAD). However, the underlying hemodynamics remains unclear. Aim of the present work is to computationally explore whether and to what extent ventricular rate during AF affects the coronary perfusion. Methods. AF is simulated at different ventricular rates (50, 70, 90, 110, 130 bpm) through a 0D-1D multiscale validated model, which combines the left heart-arterial tree together with the coronary circulation. Artificially-built …
Blood Pressure (BP) and Heart Rate (HR) provide information on clin-ical condition along 24h. Both signals present circadian changes due to sympa-thetic/parasympathetic control system that influence the relationship between them. Moreover, also the gender could modify this relation, acting on both con-trol systems. Some studies, using office measurements examined the BP/HR re-lation, highlighting a direct association between the two variables, linked to sus-pected coronary heart disease. Nevertheless, till now such relation has not been studied yet using ambulatory technique that is known to l…
We present a new computational model for the numerical simulation of blood flow in the human left heart. To this aim, we use the Navier-Stokes equations in an Arbitrary Lagrangian Eulerian formulation to account for the endocardium motion and we model the cardiac valves by means of the Resistive Immersed Implicit Surface method. To impose a physiological displacement of the domain boundary, we use a 3D cardiac electromechanical model of the left ventricle coupled to a lumped-parameter (0D) closed-loop model of the remaining circulation. We thus obtain a one-way coupled electromechanics-fluid d…
Using a three-compartment model of blood pressure dynamics, we analyze theoretically the short term cardiovascular variability: how the respiratory-related blood pressure fluctuations are buffered by appropriate heart rate changes: i.e. the respiratory sinus arrhythmia. The buffering is shown to be crucially dependent on the time delay between the stimulus (such as e.g. the inspiration onset) and the application of the control (the moment in time when the efferent response is delivered to the heart). This theoretical analysis shows that the buffering mechanism is effective only in the upright …
Cardiac disease and clinical intervention may both lead to an increased risk for thrombosis events due to modified blood flow in the heart, and thereby a change in the mechanical stimuli of blood cells passing through the chambers of the heart. Specifically, the degree of platelet activation is influenced by the level and type of mechanical stresses in the blood flow. Here we analyze the blood flow in the left ventricle of the heart through a computational model constructed from patient-specific data. The blood flow in the ventricle is modeled by the Navier-Stokes equations, and the flow throu…
This Artificial left ventricle is based on a simple conic assumption shape for left ventricle where its motion is made by attached compressed elastic tubes to its walls which are regarded to electrical points at each nodal .This compressed tubes are playing the role of myofibers in the myocardium of the left ventricle. These elastic tubes have helical shapes and are transacting on these helical bands dynamically. At this invention we give an algorithm of this artificial left ventricle construction that of course the effect of the blood flow in LV is observed with making beneficiary used of sen…
The simulation of blood flow and pressure in arteries requires outflow boundary conditions that incorporate models of downstream domains. We previously described a coupled multidomain method to couple analytical models of the downstream domains with 3D numerical models of the upstream vasculature. This prior work either included pure resistance boundary conditions or impedance boundary conditions based on assumed periodicity of the solution. However, flow and pressure in arteries are not necessarily periodic in time due to heart rate variability, respiration, complex transitional flow or acute…
The cardiovascular system is composed of the heart, blood and blood vessels. Regarding the heart, cardiac conditions are determined by the electrocardiogram, that is a noninvasive medical procedure. In this work, we propose autoregressive process in a mathematical model based on coupled differential equations in order to model electrocardiogram signals. Our results are compared with experimental tachogram by means of Poincaré plot and dentrended fluctuation analysis. We verify that the results from the model with autoregressive process show good agreement with experimental measures from tachog…
In this paper we show that different physiological states and pathological conditions may be characterized in terms of predictability of time series signals from the underlying biological system. In particular we consider systolic arterial pressure time series from healthy subjects and Chronic Heart Failure patients, undergoing paced respiration. We model time series by the regularized least squares approach and quantify predictability by the leave-one-out error. We find that the entrainment mechanism connected to paced breath, that renders the arterial blood pressure signal more regular, thus…
Recent developments in cardiovascular modelling allow us to simulate blood flow in an entire human body. Such model can also be used to create databases of virtual subjects, with sizes limited only by computational resources. In this work, we study if it is possible to estimate cardiovascular health indices using machine learning approaches. In particular, we carry out theoretical assessment of estimating aortic pulse wave velocity, diastolic and systolic blood pressure and stroke volume using pulse transit/arrival timings derived from photopletyshmography signals. For predictions, we train Ga…
Today's diagnostics include devices such as pulse oximeters, blood pressure monitors, and temperature measurements. These devices provide vital information to medical personnel when making treatment decisions. Drawing inspiration from the fundamental utility of pulse oximeters, we present a methodology for a robust low-cost approach to imaging subsurface vasculature and monitoring heart rate. The approach uses off-the-shelf equipment, set up in free space without physical contact and exploits the nature of the interaction between light at near-infrared wavelengths with tissue. Image processing…
With the development of additive manufacturing, 3D printing technology has become more common nowadays. We designed and 3D printed a cost-effective liquid fluid pressure measurement device that can convert liquid pressure to air pressure. Air pressure was measured by a low-cost manometer in this study. The device can measure the pressure drop across artificial aortic heart valves at different flow rate conditions. The main objective of this study is to utilize 3D printing technology to measure pressure loss through artificial aortic heart valves. From the measured pressure drop, the energy los…
Myocardial blood flow (MBF) and flow reserve are usually quantified in the clinic with positron emission tomography (PET) using a perfusion-specific radiotracer (e.g. 82Rbchloride). However, the clinical accessibility of existing perfusion tracers remains limited. Meanwhile, 18F-fluorodeoxyglucose (FDG) is a commonly used radiotracer for PET metabolic imaging without similar limitations. In this paper, we explore the potential of 18F-FDG for myocardial perfusion imaging by comparing the myocardial FDG delivery rate K1 with MBF as determined by dynamic 82Rb PET in fourteen human subjects with h…
Purpose: To show some preliminary results about the possibility to exploit a cardiovascular mathematical model - made patient-specific by noninvasive data routinely measured during ordinary clinical examinations - in order to obtain sufficiently accurate central blood pressure (BP) estimates. Methods: A closed-loop multiscale (0D and 1D) model of the cardiovascular system is made patient-specific by using as model inputs the individual mean heart rate and left-ventricular contraction time, weight, height, age, sex and mean/pulse brachial BPs. The resulting framework is used to determine centra…