arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1904.07620physics.med-phq-bio.TO
收藏

心房颤动时高心率时冠状动脉血流受损:多尺度模型研究

Impaired coronary blood flow at higher heart rates during atrial fibrillation: investigation via multiscale modelling

Stefania Scarsoglio, Caterina Gallo, Andrea Saglietto, Luca Ridolfi, Matteo Anselmino

摘要:

背景已经提出了不同的机制,将心房颤动(AF)和冠状动脉血流障碍,即使在没有相关的冠状动脉疾病(CAD)。然而,潜在的血流动力学仍不清楚。本工作的目的是通过计算探讨房颤期间心室率是否以及在多大程度上影响冠状动脉灌注。方法.通过0 D-1D多尺度验证模型在不同心室率(50、70、90、110、130 bpm)下模拟AF,该模型将左心动脉树与冠状动脉循环结合在一起。精确构建的RR随机提取模拟\emph{in vivo}跳动特征。计算的所有血流动力学参数均基于左前降支(LAD)动脉,并考虑了冠状动脉血流的波形、振幅和灌注。结果冠状动脉血流动力学的改变被发现与心率增加相关,这强烈地改变了LAD流速的波形和振幅,并且与心跳到心跳的变异性相关。后者在冠状动脉循环中随着HR的增长而整体放大,即使输入RR变异性在所有HR处保持恒定。结论.房颤时较高的心室率会造成整体冠状动脉血流受损和心肌氧供需比失衡。心率的增加和AF引起的血流动力学变异性的增加导致AF中冠状动脉灌注损伤超过90-110 bpm。此外,发现冠状动脉灌注压(CPP)不再是HR高于90 bpm的心肌灌注的良好测量。

英文摘要:

Background. Different mechanisms have been proposed to relate atrial fibrillation (AF) and coronary flow impairment, even in absence of relevant coronary artery disease (CAD). However, the underlying hemodynamics remains unclear. Aim of the present work is to computationally explore whether and to what extent ventricular rate during AF affects the coronary perfusion. Methods. AF is simulated at different ventricular rates (50, 70, 90, 110, 130 bpm) through a 0D-1D multiscale validated model, which combines the left heart-arterial tree together with the coronary circulation. Artificially-built RR stochastic extraction mimics the \emph{in vivo} beating features. All the hemodynamic parameters computed are based on the left anterior descending (LAD) artery and account for the waveform, amplitude and perfusion of the coronary blood flow. Results. Alterations of the coronary hemodynamics are found to be associated either to the heart rate increase, which strongly modifies waveform and amplitude of the LAD flow rate, and to the beat-to-beat variability. The latter is overall amplified in the coronary circulation as HR grows, even though the input RR variability is kept constant at all HRs. Conclusions. Higher ventricular rate during AF exerts an overall coronary blood flow impairment and imbalance of the myocardial oxygen supply-demand ratio. The combined increase of heart rate and higher AF-induced hemodynamic variability lead to a coronary perfusion impairment exceeding 90-110 bpm in AF. Moreover, it is found that coronary perfusion pressure (CPP) is no longer a good measure of the myocardial perfusion for HR higher than 90 bpm.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑