A theoretical approach to determine the optimal form of the near-field optical microscope probe is proposed. An analytical expression of the optimal probe form with subwavelength aperture has been obtained. The advantages of the probe with the optimal form are illustrated using numerical calculations. The conducted calculations show 10 times greater light throughput and the reception possibility of the more compactly localized light at the output probe aperture which could indicate better spatial resolution of the optical images in near-field optical technique using optimal probe.
We extend image scanning microscopy to second harmonic generation (SHG) by extracting the complex field amplitude of the second-harmonic beam. While the theory behind coherent image scanning microscopy (ISM) is known, an experimental demonstration wasn't yet established. The main reason is that the naive intensity-reassignment procedure cannot be used for coherent scattering as the point spread function is now defined for the field amplitude rather than for the intensity. We use an inline interferometer to demonstrate super-resolved phase-sensitive SHG microscopy by applying the ISM reassignme…
Super-resolution optical microscopy is a rapidly evolving scientific field dedicated to imaging sub-wavelength sized objects, leaving its mark in multiple branches of biology and technology. While several super-resolution optical microscopy methods have become a common tool in life science imaging, new methods, supported by cutting-edge technology, continue to emerge. One rather recent addition to the super-resolution toolbox, image scanning microscopy (ISM), achieves an up to twofold lateral resolution enhancement in a robust and straightforward manner. To further enhance ISM's resolution in …
A fluorescence correlation spectroscopy (FCS) system based on two independent measurement volumes is presented. The optical setup and data acquisition hardware are detailed, as well as a complete protocol to control the location, size and shape of the measurement volumes. A method that allows to monitor independently the excitation and collection efficiency distribution is proposed. Finally, a few examples of measurements that exploit the two spots in static and/or scanning schemes, are reported.
We report an experimental technique to map and exploit the local density of optical states of arbitrary planar nano-photonic structures. The method relies on positioning a spontaneous emitter attached to a scanning probe deterministically and reversibly with respect to its photonic environment while measuring its lifetime. We demonstrate the method by imaging the enhancement of the local density of optical states around metal nanowires. By nano-positioning, the decay rate of a pointlike source of fluorescence can be reversibly and repeatedly changed by a factor of two by coupling it to the gui…
We demonstrate a simple scheme for high-resolution imaging of nanoplasmonic structures that basically removes most of the resolution limiting allowed light usually transmitted to the far field. This is achieved by implementing a Fourier lens in a near-field scanning optical microscope (NSOM) operating in the leakage-radiation microscopy (LRM) mode. The method consists of reconstructing optical images solely from the plasmonic `forbidden' light collected in the Fourier space. It is demonstrated by using a point-like nanodiamond-based tip that illuminates a thin gold film patterned with a sub-wa…
The finite-difference time-domain (FDTD) method is employed to solve the three dimensional Maxwell equation for the situation of near-field microscopy using a sub-wavelength aperture. Experimental result on unexpected high spatial resolution is reproduced by our computer simulation.
Scattering scanning near-field optical microscopy enables optical imaging and characterization of plasmonic devices with nanometer-scale resolution well below the diffraction limit. This technique enables developers to probe and understand the waveguide-coupled plasmonic antenna in as-fabricated heat-assisted magnetic recording heads. In order validate and predict results and to extract information from experimental measurements that is physically comparable to simulations, a model was developed to translate the simulated electric field into expected near-field measurements using physical para…
The scanning mid-IR-laser microscopy was previously demonstrated as an effective tool for characterization of different semiconductor crystals. Now the technique has been successfully applied for the investigation of CZ SixGe1-x -- a promising material for photovoltaics - and multicrystalline silicon for solar cells. In addition, this technique was shown to be appropriate for imaging of polishing-induced defects as well as such huge defects as "pin holes". Besides, previously unexplained "anomalous" (cubic power) dependence of signal of the scanning mid-IR-laser microscope in the optical-beam-…
Photobleaching is a major limitation of superresolution Stimulated Depletion Emission (STED) microscopy. Fast scanning has long been considered an effective means to reduce photobleaching in fluorescence microscopy, but a careful quantitative study of this issue is missing. In this paper, we show that the photobleaching rate in STED microscopy is slowed down and fluorescence yield is enhanced by scanning with high linear speed, enabled by the large field of view in our custom-built resonant-scanning STED microscope. The effect of scanning speed on photobleaching and fluorescence yield is more …
Confocal and multiphoton microscopy are effective techniques to obtain high-contrast images of 2-D sections within bulk tissue. However, scattering limits their application to depths only up to ~1 millimeter. Multimode fibers make excellent ultrathin endoscopes that can penetrate deep inside the tissue with minimal damage. Here, we present Multiview Scattering Scanning Imaging Confocal (MUSSIC) Microscopy that enables high signal-to-noise ratio (SNR) imaging through a multimode fiber, hence combining the optical sectioning and resolution gain of confocal microscopy with the minimally invasive …
We study the dynamic response of a mechanical quartz tuning fork in the temperature range from 9 K to 300 K. Since the quality factor Q of the resonance strongly depends on temperature, we implement a procedure to control the quality factor of the resonance. We show that we are able to dynamically change the quality factor and keep it constant over the whole temperature range. This procedure is suitable for applications in scanning probe microscopy.
Scanning laser confocal holographic microscopy using a spatial heterodyne detection method is presented. Spatial heterodyne detection technique employs a Mach-Zehnder interferometer with the reference beam frequency shifted by two acousto-optic modulators (AOM) relative to the object beam frequency. Different from the traditional temporal heterodyne detection technique in which hundreds temporal samples are taken at each scanning point to achieve the complex signal, the spatial heterodyne detection technique generates spatial interference fringes by use of a linear tempo-spatial relation provi…
Guided modes in anisotropic two-dimensional van der Waals materials are experimentally investigated and their refractive indices in visible wavelengths are extracted. Our method involves near-field scanning optical microscopy of waveguide (transverse electric) and surface plasmon polariton (transverse magnetic) modes in h-BN/SiO2/Si and Ag/h-BN stacks, respectively. We determine the dispersion of these modes and use this relationship to extract anisotropic refractive indices of h-BN flakes. In the wavelength interval 550-700 nm, the in-plane and out-of-plane refractive indices are in the range…
Recent progress in phase modulation using nanofabricated electron holograms has demonstrated how the phase of an electron beam can be controlled. In this paper, we apply this concept to the correction of spherical aberration in a scanning transmission electron microscope and demonstrate an improvement in spatial resolution. Such a holographic approach to spherical aberration correction is advantageous for its simplicity and cost-effectiveness.
Temporal focusing two-photon microscopy enables high resolution imaging of fine structures in vivo over a large volume. A limitation of temporal focusing is that signal-to-background ratio and resolution degrade rapidly with increasing imaging depth. This degradation originates from the scattered emission photons are widely distributed resulting in a strong background. We have developed Multiline Orthogonal Scanning Temporal Focusing (mosTF) microscopy that overcomes this problem. mosTF captures a sequence of images at each scan location of the excitation line, followed by a reconstruction alg…
A theory is presented to describe the heat-flux radiated in near-field regime by a set of interacting nanoemitters held at different temperatures in vacuum or above a solid surface. We show that this thermal energy can be focused and even amplified in spots that are much smaller than those obtained with a single thermal source. We also demonstrate the possibility to locally pump heat using specific geometrical configurations. These many body effects pave the way to a multi-tip near-field scanning thermal microscopy which could find broad applications in the fields of nanoscale thermal manageme…
Efficient imaging of biomolecules, 2D materials and electromagnetic fields depends on retrieval of the phase of transmitted electrons. We demonstrate a method to measure phase in a scanning transmission electron microscope using a nanofabricated diffraction grating to produce multiple probe beams. The measured phase is more interpretable than phase-contrast scanning transmission electron microscopy techniques without an off-axis reference wave, and the resolution could surpass that of off-axis electron holography. We apply the technique to image nanoparticles, carbon sub- strates and electric …
The microwave properties of nano-scale structures are important in a wide variety of applications in quantum technology. Here we describe a low-power cryogenic near-field scanning microwave microscope (NSMM) which maintains nano-scale dielectric contrast down to the single microwave photon regime, up to $10^{9}$ times lower power than in typical NSMMs. We discuss the remaining challenges towards developing nano-scale NSMM for quantum coherent interaction with two-level systems as an enabling tool for the development of quantum technologies in the microwave regime.
The principles of quantum optics have yielded a plethora of ideas to surpass the classical limitations of sensitivity and resolution in optical microscopy. While some ideas have been applied in proof-of-principle experiments, imaging a biological sample has remained challenging mainly due to the inherently weak signal measured and the fragility of quantum states of light. In principle, however, these quantum protocols can add new information without sacrificing the classical information and can therefore enhance the capabilities of existing super-resolution techniques. Image scanning microscop…