用受激发射探测器测量铯原子6S-7S宇称违反跃迁振幅的精度为2 \times 10^{-13}原子单位
Measurement of the parity violating 6S-7S transition amplitude in cesium achieved within 2 \times 10^{-13} atomic-unit accuracy by stimulated-emission detection
摘要:
我们利用受激发射的不对称放大过程,为测量高度禁戒原子跃迁中的宇称破坏(PV)提供了一种新颖的方法。该方法涉及的手征,瞬态,光学增益的铯蒸汽上的7S-6 P_{3/2}过渡,探测后,它是由一个强烈的,线性偏振,共线激光激发,调谐到共振的一个超精细线的禁止6S-7S过渡在纵向电场。我们在这里报告说,与我们以前的结果相比,一秒测量灵敏度增加了3.5倍,随后统计准确度降低了3.5倍[J. Guéna et al.,物理修订版信函90,143001(2003)]。决定性的改进,设置包括增加重复率,更好地消光的探测光束在年底的探测脉冲,并为第一次,据我们所知,以下内容:一个偏振倾斜放大器,准抑制光束反射的细胞窗口,和一个Cs细胞与导电窗口。我们还提出了系统效应的实时测试,数据的一致性检查,以及原子信号中原子所见电场的1%准确度测量。在七个不同的蒸汽电池中进行的PV测量在统计误差范围内一致。在我们目前的相对统计精度为2.6%的范围内,我们目前的结果与更精确的Boulder结果是相容的,对应于E_1^{pv}的2 \times 10^{-13}原子单位的不确定度。进一步测量的理论动机强调,我们给出了一个简短的概述,最近的建议,将允许的不确定性降低到0.1%的水平,通过创造条件,不对称放大更大。
英文摘要:
We exploit the process of asymmetry amplification by stimulated emission which provides an original method for parity violation (PV) measurements in a highly forbidden atomic transition. The method involves measurements of a chiral, transient, optical gain of a cesium vapor on the 7S-6P_{3/2} transition, probed after it is excited by an intense, linearly polarized, collinear laser, tuned to resonance for one hyperfine line of the forbidden 6S-7S transition in a longitudinal electric field. We report here a 3.5 fold increase, of the one-second-measurement sensitivity, and subsequent reduction by a factor of 3.5 of the statistical accuracy compared with our previous result [J. Guéna et al., Phys. Rev. Lett. 90, 143001 (2003)]. Decisive improvements to the set-up include an increased repetition rate, better extinction of the probe beam at the end of the probe pulse and, for the first time to our knowledge, the following: a polarization-tilt magnifier, quasi-suppression of beam reflections at the cell windows, and a Cs cell with electrically conductive windows. We also present real-time tests of systematic effects, consistency checks on the data, as well as a 1% accurate measurement of the electric field seen by the atoms, from atomic signals. PV measurements performed in seven different vapor cells agree within the statistical error. Our present result is compatible with the more precise Boulder result within our present relative statistical accuracy of 2.6%, corresponding to a 2 \times 10^{-13} atomic-unit uncertainty in E_1^{pv}. Theoretical motivations for further measurements are emphasized and we give a brief overview of a recent proposal that would allow the uncertainty to be reduced to the 0.1% level by creating conditions where asymmetry amplification is much greater.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。