We report the demonstration of a sensitive absolute gravity gradiometer based on light-pulse atom interference techniques. The gradiometer consists of two absolute accelerometers operated in a differential mode. We report a differential acceleration sensitivity of 4e-9 g/Hz^(1/2) and an inferred differential acceleration accuracy of less than 1e-9 g. This corresponds to a gravity gradient sensitivity of 4 E/Hz^(1/2) [1 E = 1e-9 s^(-2)] and an accuracy of better than 1 E for a 10 m separation between accelerometers. We demonstrate that the instrument can be used to detect nearby masses in a vibrationally noisy environment and characterize instrument sensitivity to spurious acceleration and rotation noise.
We here present a high sensitivity gravity-gradiometer based on atom interferometry. In our apparatus, two clouds of laser-cooled rubidium atoms are launched in fountain configuration and interrogated by a Raman interferometry sequence to probe the gradient of gravity field. We recently implemented a high-flux atomic source and a newly designed Raman lasers system in the instrument set-up. We discuss the applications towards a precise determination of the Newtonian gravitational constant G. The long-term stability of the instrument and the signal-to-noise ratio demonstrated here open interesti…
We have realized a magnetic tensor gradiometer by interferometrically measuring the relative phase between two spatially separated Bose-Einstein condensates (BECs). We perform simultaneous Ramsey interferometry of the proximate $^{87}$Rb spin-1 condensates in freefall and infer their relative Larmor phase -- and thus the differential magnetic field strength -- with a common-mode phase noise suppression exceeding $50\,\mathrm{dB}$. By appropriately biasing the magnetic field and separating the BECs along orthogonal directions, we measure the magnetic field gradient tensor of ambient and applied…
We propose new multi-dimensional atom optics that can create coherent superpositions of atomic wavepackets along three spatial directions. These tools can be used to generate light-pulse atom interferometers that are simultaneously sensitive to the three components of acceleration and rotation, and we discuss how to isolate these inertial components in a single experimental shot. We also present a new type of atomic gyroscope that is insensitive to parasitic accelerations and initial velocities. The ability to measure the full acceleration and rotation vectors with a compact, high-precision, l…
Cold-atom inertial sensors target several applications in navigation, geoscience and tests of fundamental physics. Reaching high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where 3 atomic clouds are interrogated simultaneously in an atom interferometer featuring a 3.75 Hz sampling rate and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise, and allows us to perform dynami…
We present a compact $^{87}$Rb atomic source for high precision dual atom interferometers. The source is based on a double-stage magneto-optical trap (MOT) design, consisting of a 2-dimensional (2D)-MOT for efficient loading of a 3D-MOT. The accumulated atoms are precisely launched in a horizontal moving molasses. Our setup generates a high atomic flux ($>10^{10}$ atoms/s) with precise and flexibly tunable atomic trajectories as required for high resolution Sagnac atom interferometry. We characterize the performance of the source with respect to the relevant parameters of the launched atoms, i…
The A. Roura technique was modified to eliminate all terms in the atom interferometer phase, which are linear in the gravity-gradient tensor. The full elimination occurs if all effective wave vectors are slightly changed. The full elimination technique would allow to relieve the synchronization requirements in the test of the Einstein equivalence principle. This technique also eliminates the error of the absolute gravity measurement associated with the gravity gradient terms. The error becomes three orders smaller and does not depend on the time delay between the Raman pulses. In addition, the…
We focus on the fact that light-pulse atom interferometers measure the atoms' acceleration with only three data points per drop. As a result, the measured effect of the gravity gradient is systematically larger than the true one, an error linear with the gradient and quadratic in time almost unnoticed so far. We show how this error affects the absolute measurement of the gravitational acceleration $g$ as well as ground and space experiments with gradiometers based on atom interferometry such as those designed for space geodesy, the measurement of the universal constant of gravity and the detec…
We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 μGal.
We report on the comparison between three absolute gravimeters that took place in April 2010 at Laboratoire National de Métrologie et d'Essais. The three instruments (FG5#209 from METAS, Switzerland, IMGC-02 from INRIM, Italy, and CAG from LNE-SYRTE, France) rely on different methods: optical and atomic interferometry. We discuss their differences as well as their similarities. We compare their measurements of the gravitational acceleration in 4 points of the same pillar, in the perspective of an absolute determination of g for a watt balance experiment
We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter and FG5X\#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at the beginning of the last International Comparison of Absolute Gravimeters, ICAG-2013. We analyse a 2h10 duration common measurement, and find that the CAG shows better immunity with respect to change…
Gravimetry is a well-established technique for the determination of sub-surface mass distribution needed in several fields of geoscience, and various types of gravimeters have been developed over the last 50 years. Among them, quantum gravimeters based on atom interferometry have shown top-level performance in terms of sensitivity, long-term stability and accuracy. Nevertheless, they have remained confined to laboratories due to their complex operation and high sensitivity to the external environment. Here we report on a novel, transportable, quantum gravimeter that can be operated under real …
Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring simultaneously the absolute values of both gravitational acceleration, $g$, and its vertical gradient, $Γ_{zz}$. While the sensitivity to g is competitive with the best industrial gravimeters, the sensitivity on $Γ_{zz}$ reaches the limit set by quantum projection noise-leading to an unprecedented long-term stability of 0.1 E ($1E=1\times 10^{-9}s^{-2}$). Thi…
We combine the Ramsey interferometry protocol, the Stern-Gerlach detection scheme, and the use of elongated geometry of a cloud of fully polarized cold cesium atoms to measure the selected component of the magnetic field gradient along the atomic cloud in a single shot. In contrast to the standard method where the precession of two spatially separated atomic clouds is simultaneously measured to extract their phase difference, which is proportional to the magnetic field gradient, we here demonstrate a gradiometer using a single image of an expanding atomic cloud with the phase difference imprin…