arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.35657quant-ph
收藏

基于自旋误差的量子启发与优化的CT重建

Quantum-Inspired and Optimization-Based CT Reconstruction Through Spin-Error

Dongguk University(东国大学);Quantum Research Center, QTomo(QTomo量子研究中心);CSIRO(澳大利亚联邦科学与工业研究组织);Chungbuk Quantum Research Center, Chungbuk National University(忠北国立大学忠北量子研究中心)

Hyunju Lee, Jeonghwa Lee, Yushuang Sam Yang, Clement Chu, Anthony B. Murphy, Kyungtaek Jun

AI总结:

该研究针对量子优化CT重建规模化难题,研究模拟退火结合自旋误差缓解的方法,在不同视角及损坏条件下提升了重建精度,为大规模量子CT重建提供了基准。

摘要:

基于量子优化的计算机断层扫描(CT)重建在稀疏视角和正弦图损坏条件下,已展现出优于传统经典方法的重建精度量子优越性。然而,该方法的规模化仍具挑战性,因为更大的图像在底层二次无约束二进制优化(QUBO)模型中需要越来越多的二进制变量和交互。即使采用迭代感兴趣区域(ROI)细化,在我们的编码下,具有三个X射线质量衰减系数的60×60 ROI仍需要10800个二进制变量。作为向更大量子CT图像迈进的初始步骤,我们研究了模拟退火(SA),随后是用于优化的自旋误差缓解(SEMO),且不改变CT-QUBO目标。我们评估了三个54视角ROI重建实例和带有探测器行损坏的9视角重建,将SA和SEMO与选定的混合量子-经典求解器结果进行比较。对于ROI案例,SEMO将低预算SA输出中错误重建的像素数从13减少到1,从38减少到0,从54减少到15。在20%探测器行损坏的情况下,四对选定的SA和SEMO中有三对实现了精确重建。将SEMO应用于一个混合求解器输出,其ROI误差从78减少到1像素。改进是实例依赖的:在一个正弦图损坏案例中,QUBO能量降低而图像域误差略有增加;在一个ROI案例中,细化图像尽管QUBO能量低于真值,但仍保留15个错误像素。在评估的问题规模下,SA和SEMO达到了与选定的未缓解混合求解器结果相当或更好的重建精度,为未来更大规模、并行化的量子CT图像重建提供了初始的解决方案质量基准。

英文摘要:

Quantum-optimization-based computed tomography (CT) reconstruction has demonstrated quantum supremacy in reconstruction accuracy over conventional classical methods under sparse-view and corrupted-sinogram conditions. However, scaling this approach remains challenging because larger images require increasingly many binary variables and interactions in the underlying quadratic unconstrained binary optimization (QUBO) model. Even with iterative region-of-interest (ROI) refinement, a 60 by 60 ROI with three X-ray mass attenuation coefficients requires 10,800 binary variables under our encoding. As an initial step toward larger quantum CT images, we investigate simulated annealing (SA) followed by spin-error mitigation for optimisation (SEMO), without altering the CT-QUBO objective. We evaluate three 54-view ROI reconstruction instances and nine-view reconstruction with detector-row corruption, comparing SA and SEMO with selected hybrid quantum-classical solver results. For the ROI cases, SEMO reduced the numbers of incorrectly reconstructed pixels in low-budget SA outputs from 13 to 1, 38 to 0, and 54 to 15. With 20 percent detector-row corruption, three of four selected SA and SEMO pairs achieved exact reconstruction. Applying SEMO to one hybrid-solver output reduced its ROI error from 78 to 1 pixel. Improvements were instance-dependent: in one corrupted-sinogram case, QUBO energy decreased while image-domain error increased slightly; in one ROI case, the refined image retained 15 incorrect pixels despite having lower QUBO energy than ground truth. At the evaluated problem sizes, SA and SEMO attained reconstruction accuracy comparable to or better than selected unmitigated hybrid-solver results, providing an initial solution-quality benchmark for future larger-scale, parallelized quantum CT image reconstruction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑