arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.20650physics.flu-dynphysics.app-ph
收藏

全锥压力旋流喷雾中的韦伯数标度与液滴尺寸的距离依赖性

Weber-number scaling and the distance dependence of drop size in full-cone pressure-swirl sprays

Monash University(莫纳什大学);Bioresource Processing Research Institute of Australia (BioPRIA)(澳大利亚生物资源加工研究所);Venso Pty Ltd(Ven索有限公司)

Bilal Ben Jemaa, Vincent He, Marko Trifunović, Daniel Duke, Rishabh V. More

AI总结:

该研究针对全锥压力旋流喷雾,量化了液滴尺寸的距离依赖性,建立了含韦伯数的标度关系,明确激光衍射测液滴尺寸需同步报告测量距离的结论。

摘要:

压力旋流喷嘴将进料压力转化为旋流锥形液膜,该液膜先破碎为液丝,再进一步破碎为液滴。液滴尺寸决定了农业喷雾的沉积与漂移、空气中粉尘的捕获以及燃料喷射器的燃烧效率。测量液滴尺寸的标准工具是激光衍射,该工具会返回测量光束位置处的空间浓度加权分布。然而,所测量的液滴尺寸对喷嘴到光束的距离的依赖性尚未与韦伯数标度一同量化,因此不同距离下报告的 prefactors 无法在同等基础上进行比较。为此,我们通过激光衍射在一系列距离、压力和方位下测量了两个全锥压力旋流喷嘴的液滴尺寸分布,同时对液膜破碎过程进行了高速成像。我们发现,在液滴形成区域之外,体积中位直径 $D_{v50}$ 随测量距离 $L$ 的变化满足 $D_{v50} \sim L^{-0.18}$。对两个喷嘴的联合拟合给出 $D_{v50}/d_0 \sim \mathrm{We}^{-0.31}\\,(L/d_0)^{-0.21}$,其中 $d_0$ 为孔口直径,$\boldsymbol{\text{We}}$ 为韦伯数,该式区分了压力效应与距离效应。在固定距离下,两个喷嘴的结果与 Kooij 等人(2018)提出的 $\boldsymbol{\text{We}}^{-1/3}$ 标度吻合,所测量的距离依赖性可能解释了我们近场 prefactor 与远场值之间部分偏移的原因。因此,激光衍射测得的液滴尺寸仅在同时报告测量距离时才有意义,喷雾应在喷嘴与其目标之间的实际距离下进行表征。

英文摘要:

A pressure-swirl nozzle converts the feed pressure into a swirling conical sheet that breaks into ligaments and then into drops. The size of the drops governs the deposition and drift of agricultural sprays, the capture of airborne dust and the combustion efficiency of fuel injectors. The standard tool for measuring the drop size is laser diffraction, which returns a spatial, concentration-weighted distribution at the beam station. However, the dependence of the measured drop size on the nozzle-to-beam distance has not been quantified alongside a Weber-number scaling, so prefactors reported at different distances cannot be compared on an equal footing. To this end, we measure the drop-size distribution of two full-cone pressure-swirl nozzles by laser diffraction at a range of distances, pressures and orientations, together with high-speed imaging of the sheet breakup. We find that the volume-median diameter $D_{v50}$ decreases with the measurement distance $L$ as $D_{v50} \sim L^{-0.18}$ beyond the drop-formation region. A joint fit over both nozzles gives $D_{v50}/d_0 \sim \mathrm{We}^{-0.31}\,(L/d_0)^{-0.21}$, where $d_0$ is the orifice diameter and $\mathrm{We}$ the Weber number, which separates the pressure and distance effects. At a fixed distance the two nozzles collapse onto the $\mathrm{We}^{-1/3}$ scaling of Kooij et al. (2018), and the measured distance dependence may account for part of the offset between our near-field prefactor and the far-field value. Thus, a drop size obtained by laser diffraction is meaningful only when the measurement distance is reported with it, and a spray should be characterized at the actual distance between the nozzle and its target.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑