arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.20462cs.LG
收藏

通过示例学习:基于表格基础模型的电网稳态分析

Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model

Delft University of Technology(代尔夫特理工大学);Austrian Institute of Technology(奥地利技术研究所);University College Dublin(都柏林大学学院)

Olayiwola Arowolo, Oluwadara Adedeji, Peter Palensky, Jochen L. Cremer

AI总结:

本研究验证预训练表格基础模型TabPFN无需电力系统专用数据及微调,即可在电网稳态分析的潮流预测、事故筛选等任务中达到或优于特定任务模型,展现其作为通用神经求解器的潜力。

摘要:

基础模型已在多个科学领域展现出强大的泛化能力,但其在电力系统中的应用仍多局限于特定任务。本研究探讨预训练表格基础模型(Tabular Foundation Model, TFM)TabPFN是否可作为通用神经求解器用于电网稳态分析。我们在三项任务上评估该TFM:潮流(Power Flow, PF)预测、N-k事故筛选(N-k Contingency Screening, NCS)及电压稳定裕度(Voltage Stability Margin, VSM)预测。实验在118节点和2000节点系统上开展,将该TFM与特定任务的神经基线模型对比。无需重新训练或微调,该TFM在三项任务的多个场景中表现与最优特定任务模型相当或更优。对于118节点PF预测,该TFM的变体实现电压幅值误差为$1\times 10^{-3}$ pu、电压角度误差为$0.30^\text{o}$,优于所有基线模型;在未见过的N-1事故及接近不可行的PF案例上,该TFM与DCPF近似方法性能相当;在数百万个未见过的N-2事故上,该TFM的支路和电压违规筛选AUC分别达0.92和0.95;在标注数据有限的2000节点系统上,该TFM也实现了准确的VSM预测性能。尽管该TFM预训练时未使用任何电力系统专用数据集且无需微调,仍在测试任务中取得优异结果,这些结果展现了预训练TFM作为多种电网分析任务神经求解器的潜力。

英文摘要:

Foundation models have shown strong generalization across scientific domains, but their use in power systems remains largely task-specific. We investigate whether a pretrained tabular foundation model (TFM), TabPFN, can serve as a general-purpose neural solver for power grid steady-state analysis. We evaluate the TFM on three tasks: power flow (PF) prediction, N-k contingency screening (NCS), and voltage stability margin (VSM) prediction. We performed experiments on 118- and 2000-bus systems, comparing the TFM against task-specific neural baselines. Without retraining or fine-tuning, the TFM matches or outperforms the best task-specific model in several settings across the three tasks. For 118-bus PF prediction, a variant of the TFM achieves errors of $1\times 10^{-3}$ pu for voltage magnitudes and $0.30^\circ$ for voltage angles, outperforming all baselines. On unseen N-1 contingency and close-to-infeasible PF cases, the TFM is competitive with the DCPF approximation. For millions of unseen N-2 contingencies, the TFM achieves AUCs of 0.92 and 0.95 for branch and voltage violation screening, respectively. The TFM also attains accurate VSM prediction performance for the 2000-bus system with limited labelled data. The TFM attains strong results across the tested tasks despite pretraining without any power-system-specific dataset and requiring no fine-tuning step. These results offer a glimpse into the potential of pretrained TFMs as a neural solver for a range of power grid analysis tasks.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑