arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2603.20488cs.LG
收藏

时空网格智能:一种融合图神经网络和LSTM的混合框架用于鲁棒的电力盗窃检测

Spatio-Temporal Grid Intelligence: A Hybrid Graph Neural Network and LSTM Framework for Robust Electricity Theft Detection

Department Computer Science, Abiola Ajimobi Technical University(计算机科学系,阿比奥米博技术大学);Department of Chemical and Petroleum Engineering, Abiola Ajimobi Technical University(化学与石油工程系,阿比奥米博技术大学)

Adewale U. Oguntola, Olowookere A. AbdulQoyum, Adebukola M. Madehin, Adekemi A. Adetoro

AI总结:

本文提出一种融合时间序列异常检测、监督学习和图神经网络的混合框架,用于在不平衡数据集上高精度检测电力盗窃,实验表明该方法在准确率、召回率和精确率上均优于单一模型。

摘要:

电力盗窃,或非技术损失(NTL),对全球电力系统构成持续威胁,导致重大经济损失并损害电网稳定性。传统检测方法大多反应式且以电表为中心,难以捕捉与欺诈消费相关的复杂时空动态和行为模式。本文介绍了一种新的AI驱动的Grid Intelligence框架,融合时间序列异常检测、监督机器学习和图神经网络(GNN),以在不平衡数据集中高精度识别盗窃。利用丰富的特征集,包括滚动平均值、电压下降估计和关键电网不平衡指数,该方法采用长短期记忆(LSTM)自编码器进行时间异常评分,随机森林分类器用于表格特征区分,以及图神经网络建模配电网中的空间依赖性。实验验证显示,尽管单一异常检测方法仅获得盗窃F1分数为0.20,所提出的混合融合方法总体准确率为93.7%。通过校准决策阈值进行精度-召回分析,系统实现了盗窃的平衡精确度为0.55和召回率为0.50,有效缓解了单一模型方法中的假阳性问题。这些结果证实,整合拓扑电网意识与时间序列和监督分析提供了可扩展、基于风险的解决方案,用于主动电力盗窃检测和增强智能电网可靠性。

英文摘要:

Electricity theft, or non-technical loss (NTL), presents a persistent threat to global power systems, driving significant financial deficits and compromising grid stability. Conventional detection methodologies, predominantly reactive and meter-centric, often fail to capture the complex spatio-temporal dynamics and behavioral patterns associated with fraudulent consumption. This study introduces a novel AI-driven Grid Intelligence Framework that fuses Time-Series Anomaly Detection, Supervised Machine Learning, and Graph Neural Networks (GNN) to identify theft with high precision in imbalanced datasets. Leveraging an enriched feature set, including rolling averages, voltage drop estimates, and a critical Grid Imbalance Index, the methodology employs a Long Short-Term Memory (LSTM) autoencoder for temporal anomaly scoring, a Random Forest classifier for tabular feature discrimination, and a GNN to model spatial dependencies across the distribution network. Experimental validation demonstrates that while standalone anomaly detection yields a low theft F1-score of 0.20, the proposed hybrid fusion achieves an overall accuracy of 93.7%. By calibrating decision thresholds via precision-recall analysis, the system attains a balanced theft precision of 0.55 and recall of 0.50, effectively mitigating the false positives inherent in single-model approaches. These results confirm that integrating topological grid awareness with temporal and supervised analytics provides a scalable, risk-based solution for proactive electricity theft detection and enhanced smart grid reliability.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑