arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.20201gr-qcastro-ph.HE
收藏

引力波微透镜对广义相对论振铃测试的偏差

Biases in Ringdown Tests of General Relativity from Gravitational-Wave Microlensing

Indian Association for the Cultivation of Science(印度科学培养协会);The Inter-University Centre for Astronomy and Astrophysics (IUCAA)(大学间天文学与天体物理中心);International Centre for Theoretical Sciences, Tata Institute of Fundamental Research(塔塔基础研究所国际理论科学中心)

Sreelakshmi Mundakkal Dasan, Anuj Mishra, Apratim Ganguly

AI总结:

该研究发现引力波微透镜会在广义相对论振铃测试中产生系统偏差与虚假信号,影响残余天体参数推断及克尔假设检验。

摘要:

引力波(GW)振铃信号通过黑洞光谱学和克尔假设检验,为探测广义相对论(GR)的强场区域提供了有力工具。然而,未建模的传播效应可能会对残余天体性质的推断以及振铃特征的解释产生偏差。我们使用类GW150914的模拟信号,涵盖长波长、波动光学和几何光学 regimes,研究引力透镜对振铃推断和GR检验的影响。我们使用未透镜化的波形模型,进行互补的时域后合并分析和频域完整的旋进-合并-振铃分析。我们发现,波动光学 regime 中的透镜会在推断的残余质量和自旋中产生显著偏差,并强烈影响振铃的推断模态内容;具体而言,即使注入的信号不支持第一泛音的存在,它也会虚假地支持第一泛音的存在,其中 log₁₀ℬ²²¹₂₂₀~40。参数化振铃检验同样会产生明显支持偏离克尔准正常模(QNM)谱的结果,其中 log₁₀ℬ^modGR_GR~8。相比之下,对于此处考虑的模拟信号,高阶模的证据基本保持不变。使用整个信号进行的参数化分析进一步表明,微透镜会使推断的主导(2,2,0)QNM的频率产生偏差。这些结果表明,未建模的微透镜会在振铃分析中产生系统偏差和虚假信号,可能影响克尔假设的精度检验。

英文摘要:

Gravitational-wave (GW) ringdown signals provide a powerful probe of the strong-field regime of general relativity (GR) through black hole spectroscopy and tests of the Kerr hypothesis. However, unmodeled propagation effects can bias the inference of remnant properties and the interpretation of ringdown features. We investigate the impact of gravitational lensing on ringdown inference and tests of GR using GW150914-like simulated signals spanning the long-wavelength, wave-optics, and geometric-optics regimes. We perform complementary time-domain post-merger and frequency-domain full inspiral--merger--ringdown analyses using unlensed waveform models. We find that lensing in the wave-optics regime can produce substantial biases in the inferred remnant mass and spin and can strongly affect the inferred modal content of the ringdown. In particular, it can spuriously favor the presence of the first overtone, with $\log_{10}\mathcal{B}^{221}_{220}\sim40$, even though the injected signal has no support for it. Parameterized ringdown tests can likewise yield strong apparent support for deviations from the Kerr quasinormal mode (QNM) spectrum, with $\log_{10}\mathcal{B}^{\rm modGR}_{\rm GR}\sim8$. In contrast, the evidence for higher-order modes remains largely unchanged for the simulated signals considered here. The parameterized analysis using the entire signal further shows that microlensing can bias the inferred frequency of the dominant $(2,2,0)$ QNM. These results demonstrate that unmodeled microlensing can produce systematic biases and spurious signatures in ringdown analyses, potentially affecting precision tests of the Kerr hypothesis.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑