ELFIN任务上的高能粒子探测器仪器
The Energetic Particle Detector Instrument on ELFIN
AI总结:
本文介绍了ELFIN双小卫星任务搭载的EPD仪器的设计、实现与数据产品,该仪器用于探测地球磁层中特定能量范围的电子与离子,助力研究高能粒子分布的时间演化。
摘要:
我们介绍了电子损失与场调查(Electron Losses and Fields Investigation,ELFIN)双小卫星任务所搭载的高能粒子探测器(Energetic Particle Detector,EPD)仪器的设计方法、实现方式及数据产品。ELFIN任务旨在研究地球磁层中高能粒子分布的时间演化,于2018年至2022年期间在极地低地球轨道(Low Earth Orbit,LEO)运行。每颗卫星的有效载荷包含一对探测器头,用于探测50 keV至约5 MeV电子(EPDE)以及50 keV至约2 MeV原子离子(EPDI)的微分方向通量,能量分辨率优于50%(ΔE/E<0.5)。卫星以标称周期2.8 s旋转,旋转平面包含地球背景磁场,粒子计数间隔被细分为16个连续的自旋扇区。每个EPD搭配一台采样率为80 Hz的三轴磁通门磁强计(Fluxgate Magnetometer,FGM),用于确定局部投掷角。每个探测器头基于固体介质中的脉冲高度分析(Pulse-Height Analysis,PHA)原理工作,由矩形22.5°视场和入口光阑准直。EPDE包含6个硅探测器组成的堆叠结构,总厚度0.7 cm,几何因子为0.15 cm²·sr,通过入口箔和数字符合逻辑抑制离子污染。EPDI包含2个硅探测器组成的堆叠结构,总厚度0.1 cm,几何因子为0.03 cm²·sr,通过磁扫级和数字反符合逻辑抑制电子污染。EPD探测器头及电路板的总组装质量、体积和功耗分别为939 g、10×9.8×8.4 cm³和2.3 W。我们描述了EPD的每个设计元素,以及仪器的数据产品和处理流程。
英文摘要:
We present the design methodology, implementation, and data products of the Energetic Particle Detector (EPD) instrument on-board the Electron Losses and Fields Investigation (ELFIN) dual SmallSat mission. ELFIN was designed to study the time-evolution of energetic particle distributions in Earth's magnetosphere, having operated in polar Low Earth Orbit (LEO) from 2018 to 2022. Each satellite's instrument payload contained a pair of detector heads to sense differential-directional fluxes of 50 keV to $\sim$5 MeV electrons (EPDE), and 50 keV to $\sim$2 MeV atomic ions (EPDI), with an energy resolution better than 50% ($ΔE/E<0.5$). The satellites were spinning with a nominal period of 2.8 s in a plane containing Earth's background magnetic field, with particle counting intervals subdivided into 16 consecutive spin sectors. Each EPD was paired with a three-axis Fluxgate Magnetometer (FGM) sampled at 80 Hz for local pitch-angle determination. Each detector head operated on the principle of pulse-height analysis (PHA) in solid state media, collimated by a rectangular 22.5$^\circ$ field of view and entrance aperture. The EPDE contained a stack of 6 silicon detectors (0.7 cm total thickness) with 0.15 cm$^2$ str geometric factor, with ion contamination mitigated by an aperture foil and digital coincidence logic. The EPDI contained a stack of 2 silicon detectors (0.1 cm total thickness) with 0.03 cm$^2$ str geometric factor, with electron contamination mitigated by a magnetic broom stage and digital anti-coincidence logic. The total assembled mass, volume, and power required for the EPD detector heads and circuit boards were 939 g, 10$\times$9.8$\times$8.4 cm$^3$, and 2.3 W, respectively. We describe each EPD design element alongside instrument data products and processing.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。