Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2\,K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11\,kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.
This paper presents non-destructive dark current measurements of superconducting TESLA cavities for superconducting LINACs. The measurements were carried out in a highly disturbed accelerator environment using a low temperature superconducting d.c. SQUID based Cryogenic Current Comparator (CCC). The overall current sensitivity under these rough conditions was measured to be 0.2 nA/sqrt(Hz) which enables the detection of dark currents of 5 nA.
We report here the realization and commissioning of an experiment dedicated to the study of the optical properties of light matter hybrids constituted of crystalline samples embedded in an optical cavity. The experimental assembly developed offers the unique opportunity to study the weak and strong coupling regime between a tunable optical cavity in cryogenic environment and low energy degrees of freedom such as phonons, magnons or charge fluctuations. We describe here the setup developed which allows the positioning of crystalline samples in an optical cavity of different quality factor, the …
The hidden sector photon is a weakly interacting hypothetical particle with sub-eV mass that kinetically mixes with the photon. We describe a microwave frequency light shining through a wall experiment where a cryogenic resonant microwave cavity is used to try and detect photons that have passed through an impenetrable barrier, a process only possible via mixing with hidden sector photons. For a hidden sector photon mass of 53 $μ$eV we limit the hidden photon kinetic mixing parameter $χ< 1.7\times10^{-7}$, which is an order of magnitude lower than previous bounds derived from cavity experiment…
The ability to achieve strong-coupling has made cavity-magnon systems an exciting platform for the development of hybrid quantum systems and the investigation of fundamental problems in physics. Unfortunately, current experimental realizations are constrained to operate at a single frequency, defined by the geometry of the microwave cavity. In this article we realize a highly-tunable, cryogenic, microwave cavity strongly coupled to magnetic spins. The cavity can be tuned in situ by up to 1.5 GHz, approximately 15% of its original 10 GHz resonance frequency. Moreover, this system remains within…
We present a cryogenic setup where an optical Fabry-Perot resonator is coupled to a single-mode optical fiber with coupling efficiency above 90% at mK temperatures without realignment during cooling down. The setup is prealigned at room temperature to compensate for the thermal contraction and change of the refractive index of the optical components during cooling down. The high coupling efficiency is achieved by keeping the setup rotation-symmetric around the optical axis. The majority of the setup components are made of Invar (FeNi36) which minimizes the thermal contraction. High coupling ef…
A wide variety of applications of microwave cavities, such as measurement and control of superconducting qubits, magnonic resonators, and phase noise filters, would be well served by having a highly tunable microwave resonance. Often this tunability is desired in situ at low temperatures, where one can take advantage of superconducting cavities. To date, such cryogenic tuning while maintaining a high quality factor has been limited to $\sim500$ MHz. Here we demonstrate a three-dimensional superconducting microwave cavity that shares one wall with a pressurized volume of helium. Upon pressuriza…
The third-generation gravitational wave detectors are under development by operating the detector in cryogenic temperature to reduce the thermal noise. Silicon and sapphire are promising candidate materials for the test masses and suspension elements due to their remarkable mechanical and thermal properties at cryogenic temperature. Here we present the performances of the cryogenic thermal cycling and strength testing on hydroxide catalysis bonding between sapphire and silicon. Our results suggest that although these two materials have very different coefficients of thermal expansion, but if t…
Thermal Nyquist noise fluctuations of high-$Q$ Bulk Acoustic Wave (BAW) cavities have been observed at cryogenic temperatures with a DC Superconducting Quantum Interference Device (SQUID) amplifier. High $Q$ modes with bandwidths of few tens of milliHz produce thermal fluctuations with a Signal-To-Noise ratio of up to 23dB. The estimated effective temperature from the Nyquist noise is in good agreement with the physical temperature of the device, confirming the validity of the equivalent circuit model and the non-existence of any excess resonator self-noise. The measurements also confirm that …
High-finesse, open-geometry microcavities have recently emerged as a versatile tool for enhancing interactions between photons and material systems, with a range of applications in quantum optics and quantum information science. However, mechanical vibrations pose a considerable challenge to their operation within a closed-cycle cryostat, particularly when spatial tunability and free-space optical access are required. Here, we present the design and characterization of a system that can achieve $\sim$16 pm-rms passive mechanical stability between two high-finesse mirrors while permitting both …
We demonstrate practical accelerating gradients on a superconducting radiofrequency (SRF) accelerator cavity with cryocooler conduction cooling, a cooling technique that does not involve the complexities of the conventional liquid helium bath. A design is first presented that enables conduction cooling an elliptical-cell SRF cavity. Implementing this design, a single cell 650 MHz Nb3Sn cavity coupled using high purity aluminum thermal links to a 4 K pulse tube cryocooler generated accelerating gradients up to 6.6 MV/m at 100% duty cycle. The experiments were carried out with the cavity-cryocoo…
We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a shift in the resonance frequency. We measure a modulation and temperature independent radiation pressure induced power to frequency sensitivity of -0.15 Hz/mW and find that this is the primary factor li…
The Horizontal Test Stand (HTS) SRF Cavity and Cryomodule 1 (CM1) of eight 9-cell, 1.3GHz SRF cavities are operating at Fermilab. For the cryogenic control system, how to hold liquid level constant in the cryostat by regulation of its Joule-Thompson JT-valve is very important after cryostat cool down to 2.0 K. The 72-cell cryostat liquid level response generally takes a long time delay after regulating its JT-valve; therefore, typical PID control loop should result in some cryostat parameter oscillations. This paper presents a type of PID parameter self-optimal and Time-Delay control method us…
Open-access microcavities are a powerful tool to enhance light-matter interactions for solid-state quantum and nano systems and are key to advance applications in quantum technologies. For this purpose, the cavities should simultaneously meet two conflicting requirements - full tunability to cope with spatial and spectral inhomogeneities of a material, and highest stability under operation in a cryogenic environment to maintain resonance conditions. To tackle this challenge, we have developed a fully-tunable, open-access, fiber-based Fabry-Pérot microcavity platform which can be operated also …
We present a Michelson-Morley type experiment for testing the isotropy of the speed of light in vacuum and matter. The experiment compares the resonance frequency of an actively rotated monolithic optical cryogenic sapphire resonator against the resonance frequency of a stationary evacuated optical cavity made of ultra-low-expansion glass. The results yield an upper limit for the anisotropy of the speed of light in matter (sapphire) of Delta(c)/c < 1 x 10^-16, limited by the frequency stability of the sapphire resonator.
We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected using chirped pulse microwave spectroscopy. Here we demonstrate three significant improvements to the apparatus relative to an earlier version: (1) extension of its operating range by more than a factor of two, from 12-18 GHz to 12-26 GHz, which allows a much wider range of species to be characterized; (2) improved detection sensitivity owing to use of cryogenic…
Mechanical loss of dielectric mirror coatings sets fundamental limits for both gravitational wave detectors and cavity-stabilized optical local oscillators for atomic clocks. Two approaches are used to determine the mechanical loss: ringdown measurements of the coating quality factor and direct measurement of the coating thermal noise. Here we report a systematic study of the mirror thermal noise from room temperature to 4 K by operating reference cavities at these temperatures. The directly measured thermal noise is used to extract the corresponding mechanical loss for SiO$_2$/Ta$_2$O$_5$ coa…
Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of $5 \times 10^5$ for a selected mode.
Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS) for gravitational wave detection
National Central University(国立中央大学);Center for High Energy and High Field (CHiP), National Central University(国立中央大学高能高场中心);Institute of Physics, Academia Sinica(中央研究院物理研究所);Institute of Particle and Nuclear Studies, High Energy Acceleration Research Organization (KEK)(高能加速器研究机构粒子核研究部);National Institute of Physics, University of the Philippines - Diliman(菲律宾大学迪利曼分校国家物理研究所)
Fiber-based optical microcavities exhibit high quality factor and low mode volume resonances that make them attractive for coupling light to individual atoms or other microscopic systems. Moreover, their low mass should lead to excellent mechanical response up to high frequencies, opening the possibility for high bandwidth stabilization of the cavity length. Here, we demonstrate a locking bandwidth of 44 kHz achieved using a simple, compact design that exploits these properties. Owing to the simplicity of fiber feedthroughs and lack of free-space alignment, this design is inherently compatible…
Superconducting parametric amplifiers are commonly fabricated using planar transmission lines with a non-linear inductance provided by either Josephson junctions or the intrinsic kinetic inductance of the thin film. However, Banys et al. [1] reported non-linear behaviour in a niobium pillbox cavity, hypothesising that below Tc, the pair iris-bulk resonator would act as a superconducting contact surface exploiting a Josephson-like non-linearity. This work investigates this effect further by applying Keysight Technologies' Advanced Design System (ADS) to simulate the cavity using an equivalent c…
The need for larger mK cooling platforms is being driven by the desire to host ever growing numbers of cryogenic qubits in quantum computing platforms. As part of the Superconducting Quantum Materials and Systems Center at Fermilab funded through the Department of Energy under the National Quantum Initiative, we are developing a cryogenic platform capable of reaching millikelvin temperatures in an experimental volume of 2 meters diameter by approximately 1.5 meters in height. The platform is intended to host a three-dimensional qubit architecture based on superconducting radiofrequency acceler…
We describe the construction of an apparatus designed to realize a hybrid quantum system comprised of a cryogenically cooled mechanical oscillator and ultra-cold $^{87}$Rb atoms coupled via light. The outstanding feature of our instrument is an in-situ adjustable asymmetric all-fiber membrane-in-the-middle cavity located inside an ultra-high vacuum dilution refrigerator based cryostat. We show that Bose-Einstein condensates of $N=2\times10^6$ atoms can be produced in less than 20 s and demonstrate a single photon optomechanical coupling strength of $g_0=2π\times9$ kHz employing a high-stress S…
With the axion being a prime candidate for dark matter, there has been some recent interest in direct detection through a so called `Ferromagnetic haloscope.' Such devices exploit the coupling between axions and electrons in the form of collective spin excitations of magnetic materials with the readout through a microwave cavity. Here, we present a new, general, theoretical treatment of such experiments in a Hamiltonian formulation for strongly coupled magnons and photons, which hybridise as cavity-magnon polaritons. Such strongly coupled systems have an extended measurable dispersive regime. …
The introduction of an optical resonator can enable efficient and precise interaction between a photon and a solid-state emitter. It facilitates the study of strong light-matter interaction, polaritonic physics and presents a powerful interface for quantum communication and computing. A pivotal aspect in the progress of light-matter interaction with solid-state systems is the challenge of combining the requirements of cryogenic temperature and high mechanical stability against vibrations while maintaining sufficient degrees of freedom for in-situ tunability. Here, we present a fiber-based open…
We developed an apparatus to couple a 50-micrometer diameter whispering-gallery silica microtoroidal resonator in a helium-4 cryostat using a straight optical tapered-fiber at 1550nm wavelength. On a top-loading probe specifically adapted for increased mechanical stability, we use a specifically-developed "cryotaper" to optically probe the cavity, allowing thus to record the calibrated mechanical spectrum of the optomechanical system at low temperatures. We then demonstrate excellent thermalization of a 63-MHz mechanical mode of a toroidal resonator down to the cryostat's base temperature of 1…
We investigate a new class of galactic halo axion detection techniques based on precision frequency and phase metrology. Employing equations of axion electrodynamics, it is demonstrated how a dual mode cavity exhibits linear mode-mode coupling mediated by the axion upconversion and axion downconversion processes. The approach demonstrates phase sensitivity with an ability to detect axion phase with respect to externally pumped signals. Axion signal to phase spectral density conversion is calculated for open and closed loop detection schemes. The fundamental limits of the proposed approach come…