含逆变器型资源和大负荷的多机系统次同步振荡分析的动态相量框架
A Dynamic Phasor Framework for Analysis of Subsynchronous Oscillations in Multi-Machine Systems with IBRs and Large Loads
AI总结:
提出一种广义动态相量框架,用于分析含逆变器型资源和大负荷(如AI数据中心)的多机系统在平衡与不平衡条件下的次同步振荡,支持特征分解和快速仿真,并通过修改的IEEE系统验证。
摘要:
尽管电磁暂态(EMT)框架可以捕获次同步振荡(SSO),但它在大规模系统中面临可扩展性问题。因此,我们提出一个广义动态相量(DP)框架,用于分析在平衡和不平衡条件下,含逆变器型资源(IBR)和大负荷(如人工智能数据中心(AI DC))的多机系统中的SSO。并网跟随(GFL)和构网(GFM)型IBR在其各自的$dq$坐标系DP中建模。相比之下,多质量涡轮驱动的同步发电机(SG)的详细模型以及动态传输网络模型和负荷在$pnz$坐标系DP中表示。该框架的线性化和时不变性使我们能够进行特征分解,这是对SSO模态进行根本原因分析和阻尼控制器设计的强大工具。此外,DP建模方法有助于大规模系统的更快仿真。该广义框架通过使用IEEE第一基准模型(用于次同步谐振)和修改的IEEE 4机系统的EMTDC/PSCAD仿真进行了验证。在修改的IEEE 68节点系统(含两个GFL IBR)上展示了多个用例,以显示该框架的适用性。首先,给出了IBR引起的SSO模态的时域和频域分析。然后,提出了两种解决方案来阻尼弱阻尼SSO模态:(a)使用粒子群优化设计分散控制器,(b)将一个GFL IBR的控制替换为GFM控制。最后,研究了AI DC负荷对系统一次频率响应和SG多质量涡轮的影响。
英文摘要:
Although the electromagnetic transient (EMT) framework can capture subsynchronous oscillations (SSOs), it faces scalability issues for large-scale systems. Thus motivated, we propose a generalized dynamic phasor (DP) framework to analyze SSOs in multi-machine systems with inverter-based resources (IBRs) and large loads such as artificial intelligence data centers (AI DCs) under balanced and unbalanced conditions. The grid-following (GFL) and grid-forming (GFM) IBRs are modeled in their respective $dq$-frame DPs. In contrast, the detailed model of multi-mass turbine driven synchronous generators (SGs) along with dynamic transmission network models and loads are represented in $pnz$-frame DPs. The linearizability and time-invariance of the framework enable us to perform eigen decomposition, which is a powerful tool for root-cause analysis of SSO modes and the design of damping controllers. In addition, the DP modeling approach facilitates faster simulation of large-scale systems. The generalized framework is validated with EMTDC/PSCAD simulations using the IEEE first benchmark model for subsynchronous resonance and the modified IEEE 4-machine system. Several use cases are presented on the modified IEEE 68-bus system with two GFL IBRs to show the applicability of the framework. First, time- and frequency-domain analyses of the IBR-induced SSO mode are presented. Then, two solutions are proposed to damp the poorly damped SSO mode: (a) a decentralized controller is designed using particle swarm optimization, and (b) the control of one GFL IBR is replaced by GFM control. Finally, the impact of AI DC load on primary frequency response of the system and the multi-mass turbines of the SGs are studied.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。