arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2605.03048hep-ex
收藏

利用MicroBooNE LArTPC中多次库仑散射的详细模型改进μ子能量估计

Improved muon energy estimation using a detailed model of multiple Coulomb scattering in the MicroBooNE LArTPC

MicroBooNE Collaboration, P. Abratenko, D. Andrade Aldana, J. Asaadi, A. Ashkenazi, S. Balasubramanian, B. Baller, A. Barnard, G. Barr, D. Barrow, J. Barrow, V.… 展开作者

MicroBooNE Collaboration, P. Abratenko, D. Andrade Aldana, J. Asaadi, A. Ashkenazi, S. Balasubramanian, B. Baller, A. Barnard, G. Barr, D. Barrow, J. Barrow, V. Basque, J. Bateman, B. Behera, O. Benevides Rodrigues, S. Berkman, A. Bhat, M. Bhattacharya, V. Bhelande, A. Binau, M. Bishai, A. Blake, B. Bogart, T. Bolton, M. B. Brunetti, L. Camilleri, D. Caratelli, F. Cavanna, G. Cerati, A. Chappell, Y. Chen, J. M. Conrad, M. Convery, L. Cooper-Troendle, J. I. Crespo-Anadon, R. Cross, M. Del Tutto, S. R. Dennis, P. Detje, R. Diurba, Z. Djurcic, K. Duffy, S. Dytman, B. Eberly, P. Englezos, A. Ereditato, J. J. Evans, C. Fang, B. T. Fleming, W. Foreman, D. Franco, A. P. Furmanski, F. Gao, D. Garcia Gamez, S. Gardiner, G. Ge, S. Gollapinni, E. Gramellini, P. Green, H. Greenlee, L. Gu, W. Gu, R. Guenette, L. Hagaman, M. D. Handley, M. Harrison, S. Hawkins, A. Hergenhan, O. Hen, C. Hilgenberg, G. A. Horton-Smith, A. Hussain, B. Irwin, M. S. Ismail, C. James, X. Ji, J. H. Jo, R. A. Johnson, A. Johnson, D. Kalra, G. Karagiorgi, A. Kelly, W. Ketchum, M. Kirby, T. Kobilarcik, K. Kumar, N. Lane, J. -Y. Li, Y. Li, K. Lin, B. R. Littlejohn, L. Liu, S. Liu, W. C. Louis, X. Luo, T. Mahmud, N. Majeed, C. Mariani, J. Marshall, M. G. Manuel Alves, D. A. Martinez Caicedo, F. Martinez Lopez, S. Martynenko, A. Mastbaum, I. Mawby, N. McConkey, B. McConnell, L. Mellet, J. Mendez, J. Micallef, A. Mogan, T. Mohayai, M. Mooney, A. F. Moor, C. D. Moore, L. Mora Lepin, M. A. Hernandez Morquecho, M. M. Moudgalya, S. Mulleriababu, D. Naples, A. Navrer Agasson, N. Nayak, M. Nebot-Guinot, C. Nguyen, L. Nguyen, J. Nowak, N. Oza, O. Palamara, N. Pallat, V. Paolone, A. Papadopoulou, V. Papavassiliou, H. B. Parkinson, S. F. Pate, N. Patel, Z. Pavlovic, E. Piasetzky, K. Pletcher, I. Pophale, X. Qian, J. L. Raaf, V. Radeka, A. Rafique, M. Reggiani-Guzzo, J. Rodriguez Rondon, M. Rosenberg, M. Ross-Lonergan, I. Safa, C. Sauer, D. W. Schmitz, A. Schukraft, W. Seligman, M. H. Shaevitz, R. Sharankova, J. Shi, L. Silva, E. L. Snider, S. Soldner-Rembold, J. Spitz, M. Stancari, J. St. John, T. Strauss, A. M. Szelc, N. Taniuchi, K. Terao, C. Thorpe, D. Torbunov, D. Totani, M. Toups, A. Trettin, Y. -T. Tsai, J. Tyler, M. A. Uchida, T. Usher, B. Viren, J. Wang, L. Wang, M. Weber, H. Wei, A. J. White, S. Wolbers, T. Wongjirad, K. Wresilo, W. Wu, E. Yandel, T. Yang, L. E. Yates, H. W. Yu, G. P. Zeller, J. Zennamo, C. Zhang, Y. Zhang

AI总结:

研究利用测量μ子在探测器内因多次库仑散射产生的偏转来估计其能量,通过改进技术提升了分辨率、降低偏差并改善数据与模型一致性,相比之前工作有显著性能提升且经数据 - 模型拟合验证。

摘要:

我们提出了一种改进技术,通过测量μ子在MicroBooNE探测器内路径上因多次库仑散射(MCS)产生的偏转来估计其能量。该方法有多项创新,相比之前基于MCS的μ子能量估计器能更好地捕捉探测器非理想化情况。结果显示分辨率提高、偏差降低且数据与模型一致性更好。通过模型模拟,对于全包含事件,当μ子能量从0.1 GeV增加到2 GeV时,估计偏差在1%以内,分辨率从4.3%到10%变化;对于有粒子穿出探测器体积、至少一米重建μ子轨迹且μ子能量低于2 GeV的事件,估计偏差小于2%,分辨率在7%到17%变化。与之前工作相比有显著改进,之前工作在相同能量区域分辨率是两倍且偏差达20%。数据 - 模型拟合优度研究用于验证估计器在数据上的性能,在模型不确定性内显示出良好一致性。

英文摘要:

We present an improved technique for estimating a muon's energy by measuring the deflections along its path inside the MicroBooNE detector from multiple Coulomb scattering (MCS). This approach implements several innovations that better capture detector non-idealizations compared to previous MCS-based muon energy estimators. As a result, it achieves improved resolution, reduced bias, and better data-model agreement. Using model simulation, for fully contained events the estimated bias is within 1% and the estimated resolution varies from 4.3% to 10% as muon energy increases from 0.1 GeV to 2 GeV. For events with particles exiting the detector volume, at least a meter of reconstructed muon track, and a muon energy below 2 GeV, the estimated bias is less than 2% and the estimated resolution varies from 7% to 17% over muon energy. These demonstrate significant improvements over the performance of previous work using an MCS-based energy estimator at MicroBooNE, which achieves twice as large a resolution as well as a bias of 20% over the same energy region. Data-model goodness-of-fit studies are used to validate the estimator's performance on data, showing good agreement within model uncertainties.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑