指尖微运动作为睡眠期间呼吸信息的来源使用三轴加速度计

Fingertip Micro-Motion as a Source of Respiratory Information During Sleep Using Triaxial Accelerometers

Courant Institute of Mathematical Sciences, New York University(纽约大学柯朗数学科学研究所);PranaQ Pte. Ltd.(PranaQ私人有限公司)

Jeanne Lin, Lily Liu, Chih-Wei Hsu, Hau-Tieng Wu

AI总结:

研究通过三轴加速度计捕捉指尖微运动,探讨其在睡眠期间编码呼吸信息的能力,提出TAA-resp和RMI指标,验证其在睡眠监测中的有效性。

摘要:

目的:三轴加速度计(TAAs)广泛用于家庭医疗。本研究探讨是否在指尖记录的TAAs信号在睡眠期间编码呼吸信息,特别是即时呼吸率(IRR)和呼吸努力。方法:提出基于反导数的非线性变换将TAAs信号转换为呼吸代理,称为TAA-resp。为量化嵌入的呼吸诱导运动,应用现代时频分析工具导出指数,称为呼吸运动指数(RMI)。提出的TAA-resp和RMI在包含39次完整夜间记录的数据集上得到验证,同时有多导睡眠图(PSG)和指尖TAAs测量。建立了标记TAA-resp信号质量为好、中等或差的标准,并获得专家注释。结果:平均而言,TAA-resp在22.2%±15.6%的完整夜间记录中编码高质量的呼吸信息,某些情况下达到58.9%。TAA-resp与胸式和腹式运动的相关性比与气流更强,表明主要捕捉呼吸努力。高质量的TAA-resp提供准确的IRR估计,均方根误差为0.027±0.022 Hz。RMI在高质量片段中较高,在低质量片段中较低,其分布与生理一致,在REM、N2和N3睡眠以及无睡眠呼吸暂停或低通气事件时较高。在留一受试者交叉验证中,RMI对质量标签的预测灵敏度和特异性分别为0.74和0.75。结论:指尖安装的TAAs编码有意义的呼吸信息。利用这一未充分利用的信号可能在信道受限的环境中增强家庭睡眠监测。

英文摘要:

Objective: Triaxial accelerometers (TAAs) are widely used in home care medicine. This study investigates whether TAA signals recorded at the fingertip encode respiratory information, particularly instantaneous respiratory rate (IRR) and respiratory effort, during sleep. Method: We propose an antiderivative-based nonlinear transformation to convert TAA signals into a respiratory surrogate, termed TAA-resp. To quantify the embedded respiration-induced oscillation, a modern time-frequency analysis tool is applied to derive an index, referred to as the {\em respiratory motion index} (RMI). The proposed TAA-resp and RMI are validated on two datasets comprising 39 Asians and 10 white or African Americans with full-night recordings from simultaneous polysomnography (PSG) and a fingertip TAA measurement. Criteria for labeling TAA-resp signal quality as good, moderate, or poor are established, and two experts' independent annotations with consensus are obtained. Result: On average, TAA-resp encodes high-quality respiratory information in over 21.25%$\pm$16.11% of full-night recordings, reaching up to 58.33% in some cases. TAA-resp shows stronger correlation with thoracic and abdominal motion than with airflow, indicating predominant capture of respiratory effort. High-quality TAA-resp segments offer an accurate IRR estimate with root mean square error $0.027\pm 0.022$ Hz. RMI is higher for high-quality segments and lower for poor-quality segments, and its distribution aligns with physiology, with higher values during REM, N2, and N3 sleep and in the absence of apnea or hypopnea events. In leave-one-subject-out cross-validation, RMI predicts quality labels with 0.84 sensitivity and 0.88 specificity. Conclusion: Fingertip-mounted TAAs encode meaningful respiratory information intermittently, and our method recycles underutilized respiratory information.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑