单侧前庭功能衰竭患者静态姿势描记术与佩戴式三轴加速度计相关性和可靠性研究
Body-worn triaxial accelerometer coherence and reliability related to static posturography in unilateral vestibular failure
摘要:
由于迄今为止没有研究表明基于ACC的身体摇摆测量与前庭缺陷受试者的姿势描记术相关的实验有效性,因此本研究的目的是:i)开发和验证一种实用工具,该工具可以允许临床医生通过ACC测量耳神经病学设置中的姿势摇摆紊乱,以及ii)提供可靠的,灵敏、准确的摇摆自动分析有助于鉴别单侧前庭功能衰竭(UVF)患者。因此,一组13名患者(7名女性,6名男性;平均年龄48.6 ± 6.4岁),受UVF影响至少6个月,13名匹配的健康受试者被指示在佩戴Movit传感器时,在静态测力板姿势描记(FBP)采集期间保持直立姿势(由Captiks),3-D加速度计安装在身体质心附近的后躯干上。Pearson积矩相关分析表明ACC和FBP测试提取的4个时域和3个频域指标具有较高的对应性; t检验表明ACC的2个时域和频域参数是区分UVF受试者的可靠指标。总体而言,这些方面应进一步强调临床医生和研究人员对耳神经疾病领域这种摇摆记录技术的关注,考虑丰富可用于鉴别、诊断和治疗UVF的定量和定性信息量的可能性。总之,我们认为,目前基于ACC的摇摆测量提供了一种患者友好,可靠,廉价和有效的替代记录技术,与临床平衡和移动性测试一起,在各种情况下,以及在涉及UVF患者的诊断,随访和康复的结果研究中都是有用的。
英文摘要:
Due to the fact that no study to date has shown the experimental validity of ACC-based measures of body sway with respect to posturography for subjects with vestibular deficits, the aim of the present study was: i) to develop and validate a practical tool that can allow clinicians to measure postural sway derangements in an otoneurological setting by ACC, and ii) to provide reliable, sensitive and accurate automatic analysis of sway that could help in discriminating unilateral vestibular failure (UVF) patients. Thus, a group of 13 patients (seven females, 6 males; mean age 48.6 +/- 6.4 years) affected for at least 6 months by UVF and 13 matched healthy subjects were instructed to maintain an upright position during a static forceplate-based posturography (FBP) acquisition while wearing a Movit sensor (by Captiks) with 3-D accelerometers mounted on the posterior trunk near the body centre of mass. Pearson product moment correlation demonstrated a high level of correspondence of four time-domain and three frequency-domain measures extracted by ACC and FBP testing; in addition, t-test demonstrated that two ACC-based time- and frequency-domain parameters were reliable measures in discriminating UVF subjects. These aspects, overall, should further highlight the attention of clinicians and researchers to this kind of sway recording technique in the field of otoneurological disorders by considering the possibility to enrich the amount of quantitative and qualitative information useful for discrimination, diagnosis and treatment of UVF. In conclusion, we believe the present ACC-based measurement of sway offers a patient-friendly, reliable, inexpensive and efficient alternative recording technique that is useful - together with clinical balance and mobility tests - in various circumstances, as well as in outcome studies involving diagnosis, follow-up and rehabilitation of UVF patients.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。