arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2604.13795cs.CVcs.LG
收藏

基于Vision Transformer的淋巴瘤诊断中的人工智能应用:使用弱监督训练

Artificial intelligence application in lymphoma diagnosis with Vision Transformer using weakly supervised training

Department of Pathology and Laboratory Medicine, The University of Texas McGovern Medical School(病理学与实验室医学部,德克萨斯大学麦格诺恩医学学院);Department of Hematopathology, The University of Texas MD Anderson Cancer(血液病理学部,德克萨斯大学MD安德森癌症中心)

Nghia, Nguyen, Amer Wahed, Andy Quesada, Yasir Ali, Hanadi El Achi, Y. Helen Zhang, Jocelyn Ursua, Alex Banerjee, Sahib Kalra, L. Jeffrey Medeiros, Jie Xu

AI总结:

本文探讨了使用弱监督训练的Vision Transformer在区分间变性大细胞淋巴瘤与经典霍奇金淋巴瘤中的应用,展示了其在临床诊断中的有效性。

摘要:

Vision transformers (ViT) 已被证明能够提供更灵活的特征检测,并且在预训练数据充足时可以超越卷积神经网络 (CNN)。由于其出色的特征检测能力,我们部署了 ViT 进行间变性大细胞淋巴瘤 (ALCL) 与经典霍奇金淋巴瘤 (cHL) 的形态学分类。我们之前设计了一个在 1,200 张图像块上完全监督训练的 ViT 模型,该模型在独立测试集上实现了 100% 的诊断准确率和 1.0 的 F1 分数。由于完全监督训练在训练和测试阶段缺乏专家资源的情况下不切实际,我们最近研究了一种修改的训练数据方法(弱监督训练),并证明在每个整张图像的滑片级别自动标记训练图像块是一种更适用于临床应用的 Vision Transformer 方案。我们的 ViT 模型在 100,000 张图像块上训练,其评估指标在准确率、F1 分数和曲线下面积 (AUC) 上分别达到 91.85%、0.92 和 0.98,这些值表明该 ViT 模型在使用自动图像块提取的深度学习模块中是合适的临床模型开发工具。

英文摘要:

Vision transformers (ViT) have been shown to allow for more flexible feature detection and can outperform convolutional neural network (CNN) when pre-trained on sufficient data. Due to their promising feature detection capabilities, we deployed ViTs for morphological classification of anaplastic large cell lymphoma (ALCL) versus classic Hodgkin lymphoma (cHL). We had previously designed a ViT model which was trained on a small dataset of 1,200 image patches in fully supervised training. That model achieved a diagnostic accuracy of 100% and an F1 score of 1.0 on the independent test set. Since fully supervised training is not a practical method due to lack of expertise resources in both the training and testing phases, we conducted a recent study on a modified approach to training data (weakly supervised training) and show that labeling training image patch automatically at the slide level of each whole-slide-image is a more practical solution for clinical use of Vision Transformer. Our ViT model, trained on a larger dataset of 100,000 image patches, yields evaluation metrics with significant accuracy, F1 score, and area under the curve (AUC) at 91.85%, 0.92, and 0.98, respectively. These are respectable values that qualify this ViT model, with weakly supervised training, as a suitable tool for a deep learning module in clinical model development using automated image patch extraction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑