A vacuum-ultraviolet spectropolarimeter for an electron beam ion trap
Institute for Laser Science, The University of Electro-Communications(电子通信大学激光科学研究所);National Astronomical Observatory of Japan(日本国立天文台);National Institute for Fusion Science(国立研究开发法人核融合科学研究所)
We have developed a vacuum-ultraviolet spectropolarimeter for an electron beam ion trap (EBIT) to measure the linear polarization of emission lines from multiply charged ions around the Lyman-$α$ wavelength. The main components for polarimetry are a rotatable MgF$_2$ waveplate and a SiO$_2$/MgF$_2$ multilayer-coated fused silica plate that functions as a reflective polarizer. A grazing-incidence grating is mounted between them to provide wavelength dispersion. The polarization is determined from the intensity modulation of the spectral line as the waveplate is rotated. The performance of the spectropolarimeter was demonstrated by measuring the polarization of the $2s$--$2p_{3/2}$ transition in Li-like N$^{4+}$ (124~nm) excited by a 1000~eV electron beam in an EBIT. Clear modulation of the line intensity was observed as a function of the waveplate rotation angle. From the measured modulation amplitude, the degree of linear polarization was determined to be $P=-(0.178^{+0.014}_{-0.005})$, with the negative sign indicating that the emission is polarized predominantly perpendicular to the electron beam. This result demonstrates the capability of the present spectropolarimeter to determine polarizations with an absolute uncertainty $ΔP$ on the order of $0.01$. This instrument provides a useful tool for benchmarking magnetic-sublevel-resolved collision theories through polarization measurements of multiply charged ions excited by a unidirectional electron beam.
X-ray and extreme-ultraviolet spectra from collisions of Ar$^{18+}$ and O$^{8+}$ ions with neutrals
Max-Planck-Institut für Kernphysik(马克斯·普朗克核物理研究所);NASA Goddard Space Flight Center(美国国家航空航天局戈达德太空飞行中心);Johns Hopkins University(约翰斯·霍普金斯大学);Helmholtz-Institut Jena(亥姆霍兹耶拿研究所);GSI Helmholtzzentrum für Schwerionenforschung(GSI重离子研究中心);University of California(加利福尼亚大学);SRON, Space Research Organisation Netherlands(荷兰空间研究组织)
139 GHz UV phase-locked Raman laser system for thermometry and sideband cooling of $^9$Be$^+$ ions in a Penning trap
我们演示了两个紫外激光源的相位锁定的基本红外激光调制的第四阶边带使用电光调制器和相位锁定的一个边带的第二个基本红外激光。随后的和频产生和二次谐波产生成功地将频率偏移转换到紫外域。在139 GHz的相位锁定确认通过受激拉曼跃迁测温的$^9$的$^+$离子限制在低温潘宁陷阱。该技术可用于单$^9$ Be $^+$离子的边带冷却以及Penning阱中的共振冷却方案和基于量子逻辑的测量。
Increase of barium ion-trap lifetime via photodissociation
University of California, Los Angeles(加州大学洛杉矶分校);Challenge Institute for Quantum Computation, University of California, Los Angeles(加州大学洛杉矶分校量子计算挑战研究所);Emory University(埃默里大学);Center for Quantum Science and Engineering, University of California, Los Angeles(加州大学洛杉矶分校量子科学与工程中心)
Laboratory Calibrations of Fe XII-XIV Line-Intensity Ratios for Electron Density Diagnostics
我们用电子束离子阱测量了波长为185-205 255-276埃的FXII,XIII和XIV极紫外线的电子密度诊断线强度比。这些比率可以用作天体物理光谱的密度诊断,特别是与太阳物理学有关。我们发现,使用Fe XIII 196.53/202.04和Fe XIV 264.79/274.21和270.52A/274.21线比的密度诊断是可靠的,使用灵活原子代码计算的原子数据。另一方面,我们发现FAC理论和实验之间的一个很大的差异,为常用的Fe XII(186.85 + 186.88)/195.12线比。这些FAC理论计算给出了类似于Chianti中列出的数据的结果,这些数据通常用于分析太阳观测。我们的研究结果表明,使用Fe XII(186.85 + 186.88)/195.12和Fe XIII 196.54/202.04线比测量太阳日冕密度之间的差异可能是由于Fe XII的原子计算问题。