arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2604.06280physics.med-phcs.AI
收藏

DosimeTron:利用代理AI自动化PET/CT中的个性化蒙特卡洛辐射剂量学

DosimeTron: Automating Personalized Monte Carlo Radiation Dosimetry in PET/CT with Agentic AI

Division of Radiology, Department for Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet(卡罗林斯卡学院临床科学、干预与技术系放射学部门);Artificial Intelligence and Translational Imaging (ATI) Lab, Department of Radiology, School of Medicine, University of Crete(克里特大学医学院放射学系人工智能与转化影像实验室);Department of Nuclear Medicine and Medical Physics, Section Nuclear Medicine Huddinge, Karolinska University Hospital(卡罗林斯卡大学医院核医学与医学物理系胡丁厄核医学部门);Department of Nuclear Medicine and Medical Physics, Theranostics Trial Center, Karolinska University Hospital(卡罗林斯卡大学医院核医学与医学物理系治疗诊断试验中心);Computational Biomedicine Laboratory, Institute of Computer Science Foundation for Research and Technology Hellas (ICS - FORTH)(研究与技术基金会计算机科学研究所计算生物医学实验室)

Eleftherios Tzanis, Michail E. Klontzas, Antonios Tzortzakakis

AI总结:

本文提出DosimeTron,一种基于代理AI的系统,用于自动化PET/CT检查中的患者特定蒙特卡洛内部辐射剂量学,通过自然语言交互实现DICOM元数据提取、图像预处理、MC模拟、器官分割和剂量报告,验证了其在114例病例和22个器官上的高精度与临床可行性。

摘要:

目的:开发并评估DosimeTron,一种用于PET/CT检查中自动化患者特定蒙特卡洛内部辐射剂量学的代理AI系统。材料和方法:在回顾性研究中,DosimeTron在公开可用的PSMA-PET/CT数据集上进行评估,该数据集包含来自378名男性患者、3种扫描仪型号(18-F,n=369;68-Ga,n=228)的597例研究。系统使用GPT-5.2作为推理引擎,并通过四个Model Context Protocol服务器暴露23个工具,通过自然语言交互实现DICOM元数据提取、图像预处理、MC模拟、器官分割和剂量报告。代理性能通过涵盖单轮指令和多轮对话交换的多种提示模板评估,通过OpenTelemetry追踪监控。剂量学准确性通过Pearson's r、Lin's一致性相关系数(CCC)和Bland-Altman分析在114例病例和22个器官上验证。结果:在所有提示模板和所有运行中,未观察到执行失败、管道错误或幻觉输出。Pearson's r范围从0.965到1.000(中位数0.997;所有p < 0.001),CCC范围从0.963到1.000(中位数0.996)。19个器官的平均绝对百分比差异低于5%(中位数2.5%)。总单例处理时间(SD)为32.3(6.0)分钟。结论:DosimeTron能够自主执行复杂剂量学管道,跨多样提示配置实现了与OpenDose3D的高剂量学一致性,在可接受的处理时间内证明了代理AI在PET/CT中患者特定蒙特卡洛剂量学的可行性。

英文摘要:

Purpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations. Materials and Methods: In this retrospective study, DosimeTron was evaluated on a publicly available PSMA-PET/CT dataset comprising 597 studies from 378 male patients acquired on three scanner models (18-F, n = 369; 68-Ga, n = 228). The system uses GPT-5.2 as its reasoning engine and 23 tools exposed via four Model Context Protocol servers, automating DICOM metadata extraction, image preprocessing, MC simulation, organ segmentation, and dosimetric reporting through natural-language interaction. Agentic performance was assessed using diverse prompt templates spanning single-turn instructions of varying specificity and multi-turn conversational exchanges, monitored via OpenTelemetry traces. Dosimetric accuracy was validated against OpenDose3D across 114 cases and 22 organs using Pearson's r, Lin's concordance correlation coefficient (CCC), and Bland-Altman analysis. Results: Across all prompt templates and all runs, no execution failures, pipeline errors, or hallucinated outputs were observed. Pearson's r ranged from 0.965 to 1.000 (median 0.997; all p < 0.001) and CCC from 0.963 to 1.000 (median 0.996). Mean absolute percentage difference was below 5% for 19 of 22 organs (median 2.5%). Total per-study processing time (SD) was 32.3 (6.0) minutes. Conclusion: DosimeTron autonomously executed complex dosimetry pipelines across diverse prompt configurations and achieved high dosimetric agreement with OpenDose3D at clinically acceptable processing times, demonstrating the feasibility of agentic AI for patient-specific Monte Carlo dosimetry in PET/CT.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑