arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2603.29539stat.MEstat.AP
收藏

用于具有重复测量的协变量依赖方法一致性的树模型

Tree models for covariate-dependent method agreement with repeated measurements in clinical research

TUM School of Medicine and Health, Technical University of Munich(慕尼黑工业大学健康医学院);Faculty of Economics and Statistics, University of Innsbruck(因斯布鲁克大学经济统计学院);University Medical Center Hamburg-Eppendorf(汉堡埃彭多夫大学医学中心);Institute of AI and Informatics in Medicine, TUM School of Medicine and Health, Technical University of Munich(慕尼黑工业大学健康医学院人工智能与医学信息学研究所)

Siranush Karapetyan, Achim Zeileis, Moritz Flick, Bernd Saugel, Alexander Hapfelmeier

AI总结:

本文提出COAT树模型,用于处理临床研究中重复测量的协变量依赖方法一致性问题,通过回归树捕捉Bland-Altman分析参数与协变量的依赖关系,并通过模拟研究验证其有效性。

摘要:

背景:在临床研究中,Bland-Altman分析常用于评估两种或多种技术、设备或方法的测量一致性,也可处理每个受试者或观察单位的重复测量。然而,一个强而隐含的假设是方法一致性在不同受试者间是同质的。目的:将之前引入的多变量建模条件方法一致性分析扩展到频繁的重复测量情况。方法:适当回归树,称为条件方法一致性树(COAT),被推广以捕捉Bland-Altman分析参数与协变量的依赖关系。这些参数,即方法间差异的期望和方差,被分解为受试者特定的成分以考虑重复测量。尽管树模型的理论和渐近性质已知,但进行了模拟研究以评估COAT在有限样本中的性能。一个比较心脏输出测量设备的比较作为应用示例。结果:COAT适用于成对和非成对的重复测量两种相关情况。在模拟研究中,它在名义水平上控制了I型错误,并能随着样本量增加检测协变量依赖的方法一致性。调整的Rand指数,一个衡量估计和真实子组之间一致性的指标,达到了非常高的值,接近最大值1。心脏输出分析显示,患者特征可能影响测量设备之间的一致性,这对患者护理有启示。结论:COAT可以显式定义依赖协变量的异质方法一致性的子组,并在重复测量情况下通过适当的统计检验进行检验。

英文摘要:

Background: In clinical research, the Bland-Altman analysis is commonly used to assess agreement of metric measurements made by two or more techniques, devices or methods. The approach can also deal with repeated measurements per subject or observational unit. However, a strong and implicit assumption is that agreement of methods is homogeneous across subjects. Objective: To extend the previously introduced multivariable modeling of conditional method agreement with single measurements per subject to the frequent case of repeated measurements. Methods: Appropriate regression trees, called conditional method agreement trees (COAT), are generalized to capture the dependence of the parameters of the Bland-Altman analysis on covariates. These parameters, the expectation and variance of the differences between the methods, are decomposed into subject-specific components to account for repeated measurements. Whilst the theoretical, asymptotic properties of tree models are known, a simulation study was carried out to assess the performance of COAT in finite samples. A comparison of devices measuring cardiac output serves as an application example. Results: COAT is applicable to the two relevant cases of paired and unpaired repeated measurements. In the simulation study, it controlled the type-I error at the nominal level and could detect covariate-dependent method agreement with increasing sample size. The Adjusted Rand Index, a measure of concordance between the estimated and true subgroups, reached very high values close to the maximum of 1. The analysis of cardiac output showed that patients' characteristics may influence the agreement between measuring devices, with implications for use in patient care. Conclusion: COAT can explicitly define subgroups of heterogeneous method agreement in dependence of covariates with appropriate statistical testing in case of repeated measurements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑