arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2603.29294physics.ins-detnucl-ex
收藏

CITIUS高分辨率探测器对重带电粒子和中子的成像性能评估

Assessment of the Imaging Performance of the CITIUS High-Resolution Detector for Heavy Charged Particles and Neutrons

The University of Tokyo(东京大学);Japan Synchrotron Radiation Research Institute (JASRI)(日本同步辐射研究所);RIKEN SPring-8 Center(理化学研究所SPring-8中心)

Yoshio Kamiya, Haruki Nishino, Takaki Hatsui

AI总结:

通过实验和模拟,评估了CITIUS高速X射线探测器对α粒子和冷中子的成像性能,发现其增益选择架构和长载流子漂移距离带来的电荷共享显著提高了空间分辨率。

摘要:

我们报告了CITIUS(一种为大型同步辐射设施SPring-8-II开发的高速X射线探测器)对重带电粒子和中子的成像性能评估。为了表征探测器响应,使用$^{241}$Am源的α粒子在400V、300V、200V和170V四个反向偏压下进行了辐照实验,从而控制电荷扩散量。构建了实验的Geant4模型,并通过模板拟合测量到的信号簇形状分布确定了四个模型参数。最佳拟合值为:源的内禀能量展宽5%,Au-Pd涂层的金占比0.4,在400V反向偏压下650 μm漂移距离上的横向电荷扩散展宽26.5 μm,以及中增益通道的每像素读出噪声10000 $e^{-}$。利用获得的传感器模型,对4 MeV α粒子和冷中子进行了模拟,以评估预期的空间分辨率。在两种情况下,当CITIUS以高增益和中增益之间的增益选择模式运行时,模拟结果显示显著改善:例如,在70 μm像素尺寸下,α粒子的分辨率从9.1 μm提高到1.2 μm,冷中子的分辨率从26 μm提高到1.9 μm。这些结果表明,CITIUS的两个关键特性——其增益选择架构和长载流子漂移距离带来的大量电荷共享——将其成像能力从X射线扩展到重带电粒子和中子。

英文摘要:

We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the detector response, an irradiation experiment was performed using alpha particles from an $^{241}$Am source at four back-bias voltages of 400V, 300 V, 200 V, and 170 V, thereby controlling the amount of charge diffusion. A Geant4 model of the experiment was constructed, and four model parameters were determined by template fitting to the measured signal cluster shape distributions. The best-fit values are: an intrinsic energy spread of 5% for the source, a gold fraction of 0.4 for the Au-Pd coating, a lateral charge diffusion spread of 26.5 $μ$m over a drift distance of 650 $μ$m at 400V back-bias, and a per-pixel readout noise of 10000 $e^{-}$ in the medium-gain channel. Using the obtained sensor model, simulations were performed for 4 MeV alpha particles and cold neutrons to evaluate the expected spatial resolution. In both cases, simulated CITIUS, when operated in a gain-selecting mode between high and medium gains, yields a substantial improvement: at a pixel size of 70 $μ$m for example, the resolution improves from 9.1 $μ$m to 1.2 $μ$m for alpha particles, and from 26 $μ$m to 1.9 $μ$m for cold neutrons. These results suggest that two key features of CITIUS -- its gain-selecting architecture and the substantial charge sharing enabled by the long carrier drift distance -- extend its imaging capabilities beyond X-rays to heavy charged particles and neutrons.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑