arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2603.21668physics.flu-dyn
收藏

用于高超音速飞行气动加热评估的热成像测量与热流补偿方法的结合

Combined thermographic measurement and heat-flux compensation methods for aerodynamic heating evaluation in hypersonic flight

Institute of Fluid Science, Tohoku University(东北大学流体科学研究所)

Kento Inokuma, Aiko Yakeno, Yoshiyuki Watanabe, Kiyonobu Ohtani

AI总结:

本文提出了一种结合热成像测量和热流补偿方法的新技术,通过高速热成像和CFD模拟验证了高超音速飞行中气动加热的特征,确定了最大表面温度升高和滞止Stanton数。

摘要:

本文开发了用于评估高超音速飞行中气动加热的新热成像测量和热流补偿方法,利用高速热成像技术。一个直径为8毫米的高超音速球形弹体在弹道范围的测试段中以约5马赫的速度发射。通过阴影图成像可视化飞行轨迹和激波层。使用高速红外(IR)相机进行热成像测量以获得弹体表面温度分布。通过考虑IR相机光电探测器的响应时间和弹体轨迹的几何特性,从热成像数据中重建球形表面的温度分布。此外,为了验证激波层几何形状和气动加热特性,还进行了计算流体动力学(CFD)模拟。阴影图结果表明,在弹体前方形成了分离激波和激波层,与CFD结果一致。从热成像结果中发现,飞行过程中最大表面温度升高为环境温度以上24.4 K,并随着距离滞止点的增加而减少。通过假设飞行过程中由一维瞬态热传导引起的热量传导,从重建的表面温度估算出Stanton数分布。滞止Stanton数计算为0.00366,与CFD结果和先前报告的经验相关性一致。

英文摘要:

Novel thermographic measurement and heat-flux compensation methods combined for evaluating aerodynamic heating in hypersonic flight were developed using high-speed thermography. A hypersonic spherical projectile with a diameter of 8 mm was launched at approximately Mach 5 in the test section of a ballistic range. Shadowgraph imaging was conducted to visualize the flight trajectory and the shock layer. Thermographic measurement was performed using a high-speed infrared (IR) camera to obtain the surface temperature distribution of the projectile. The temperature distribution on the spherical surface was reconstructed from the thermographic data, by considering the photoresponse time of the photodetector of the IR camera and the geometric characteristics of the projectile trajectory. Furthermore, to validate the shock-layer geometry and aerodynamic heating characteristics, a computational fluid dynamics (CFD) simulation was also performed. The shadowgraph results showed that a detached shock wave and a shock layer were formed in front of the projectile, consistent with the CFD result. From the thermographic result, it was found that the maximum surface temperature rise during the flight was 24.4 K above the ambient temperature and it decreased with increasing distance from the stagnation point. The Stanton number distribution was estimated from the reconstructed surface temperature by assuming a one-dimensional transient heat conduction caused during the flight. The stagnation Stanton number was calculated to be 0.00366, which was also consistent with both the CFD result and a previously reported empirical correlation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑