arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2603.14858physics.atom-phquant-ph
收藏

通过多个钟跃迁的几何均值实现SI秒的定义

Realization of the SI Second Defined by Geometric Mean of Multiple Clock Transitions

National Institute of Metrology(中国计量科学研究院);Key Laboratory of Time Frequency and Gravity Primary Standard, State Administration for Market Regulation(国家市场监督管理总局时间频率与重力基准重点实验室);Department of Precision Machinery and Precision Instruments, School of Engineering Science, University of Science and Technology of China(中国科学技术大学工程科学学院精密机械与精密仪器系)

Fang Fang, Chaowei Wang, Yani Zuo, Shaoyang Dai

AI总结:

本文探讨了在不同性能水平和非重叠运行时间的多光学钟情况下,如何通过几何均值或算术均值组合实现SI秒的重新定义,并分析了死时间对氢 maser 作为飞轮参考的影响。

摘要:

当前SI秒的定义基于133Cs基态超精细跃迁在微波领域的频率,最精确的实现具有约(1-2)E16的频率分数不确定度。相比之下,最先进的光学钟显示出估计不确定度低两个到三个数量级,促使对SI秒重新定义的讨论。已提出几种新的定义选项,其中一种引入了一个常数N,定义为多个钟跃迁频率的加权几何均值。本文研究了当不是所有定义跃迁可用且多个光学钟具有不同性能水平和非重叠运行时间时,如何实际实现N。我们考虑了两种互补的实现和重建路线。一种路线基于几何均值组合,另一种基于算术均值组合。我们推导出一致的不确定性表达式,结合测量不确定性和所需的推荐频率或频率比的不确定性。通过分析三个跃迁的案例研究,我们识别出每种路线产生总不确定度较低的参数范围,并提供显式的转换条件。我们进一步探讨了当氢maser作为飞轮参考时死时间的主要作用,通过引入基于系数和协方差矩阵的时间分段、时间加权组合,以考虑重叠操作和测量间隔之间的相关性。我们的发现为减少多钟实现的总不确定度提供了实际指导,并有助于正在进行的SI秒重新定义努力。

英文摘要:

The current definition of the SI second is based on the 133Cs ground-state hyperfine transition in the microwave domain, with the most accurate realizations achieving fractional frequency uncertainties of about (1-2)E16. In contrast, state-of-the-art optical clocks now demonstrate estimated uncertainties two to three orders of magnitude lower, prompting discussion on the redefinition of the SI second. Several options for the new definition have been proposed, one of which introduces a constant N defined as the weighted geometric mean of multiple clock transition frequencies. In this work, we investigate how N can be practically realized when not all defining transitions are available and when multiple optical clocks operate with different performance levels and non-overlapping uptimes. We consider two complementary realization and reconstruction routes. One route is based on geometric-mean combinations, and the other is based on arithmetic-mean combinations. We derive consistent uncertainty expressions that incorporate both measurement uncertainties and, where required, uncertainties of recommended frequencies or frequency ratios. Using analytic three-transition case studies, we identify the parameter regimes in which each route yields a lower total uncertainty and provide explicit conditions for the crossover between them. We further address the dominant role of dead time when a hydrogen maser serves as a flywheel reference by introducing a time-segmented, time-weighted combination based on coefficient and covariance matrices, which accounts for overlapping operation and correlations across measurement intervals. Our findings offer practical guidance for minimizing total uncertainty in multi-clock realizations and contribute to ongoing efforts toward redefining the SI second.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑