Realization of the SI Second Defined by Geometric Mean of Multiple Clock Transitions
National Institute of Metrology(中国计量科学研究院);Key Laboratory of Time Frequency and Gravity Primary Standard, State Administration for Market Regulation(国家市场监督管理总局时间频率与重力基准重点实验室);Department of Precision Machinery and Precision Instruments, School of Engineering Science, University of Science and Technology of China(中国科学技术大学工程科学学院精密机械与精密仪器系)
The current definition of the SI second is based on the 133Cs ground-state hyperfine transition in the microwave domain, with the most accurate realizations achieving fractional frequency uncertainties of about (1-2)E16. In contrast, state-of-the-art optical clocks now demonstrate estimated uncertainties two to three orders of magnitude lower, prompting discussion on the redefinition of the SI second. Several options for the new definition have been proposed, one of which introduces a constant N defined as the weighted geometric mean of multiple clock transition frequencies. In this work, we investigate how N can be practically realized when not all defining transitions are available and when multiple optical clocks operate with different performance levels and non-overlapping uptimes. We consider two complementary realization and reconstruction routes. One route is based on geometric-mean combinations, and the other is based on arithmetic-mean combinations. We derive consistent uncertainty expressions that incorporate both measurement uncertainties and, where required, uncertainties of recommended frequencies or frequency ratios. Using analytic three-transition case studies, we identify the parameter regimes in which each route yields a lower total uncertainty and provide explicit conditions for the crossover between them. We further address the dominant role of dead time when a hydrogen maser serves as a flywheel reference by introducing a time-segmented, time-weighted combination based on coefficient and covariance matrices, which accounts for overlapping operation and correlations across measurement intervals. Our findings offer practical guidance for minimizing total uncertainty in multi-clock realizations and contribute to ongoing efforts toward redefining the SI second.
Realization of a fast triple-magic all-optical qutrit in strontium-88
Max-Planck-Institut für Quantenoptik(马克斯·普朗克量子光学研究所);Munich Center for Quantum Science and Technology (MCQST)(慕尼黑量子科学与技术中心);Fakultät für Physik, Ludwig-Maximilians-Universität(路德维希-马克西米利安大学物理学院)
Optical lattice clocks with weakly bound molecules
光学分子钟对电子与质子质量比的时间变化具有无与伦比的灵敏度,并有望洞察标准模型之外可能的新物理。我们提出用玻色子$^{174}$ Yb $_2$分子实现一个分子钟,其中禁戒的$^1$ S $_0$ $\rightarrow$ $^3$ P $_0$时钟跃迁将被磁诱导.玻色子物质的使用避免了由于费米子物质中存在的超精细结构而导致的可能的复杂性。虽然直接的时钟线光缔合将是具有挑战性的,但弱结合的基态分子可以通过STIRAP产生并代替使用。最近的散射测量[L. Franchi等人,New J. Phys 19,103037(2017)]使我们能够确定目标$^1$ S $_0$ + $^3$ P $_0$振动能级的位置,并计算基态和激发分子态之间时钟跃迁的Franck-Condon因子。由此产生的磁感应拉比频率与原子的频率相似,暗示实验实现是可行的。成功的观察可以为赫兹级分子光谱学铺平道路。