MAP-Diff: 多锚点引导的扩散模型用于渐进式三维全身低剂量PET去噪

MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising

School of Engineering, Zurich University of Applied Sciences, CH;Bioengineering Department;Imperial-X, Imperial College London, UK;DAMTP, University of Cambridge, UK;Lucerne University Teaching;Research Hospital, CH;Lung Institute, Imperial College London, UK;Cardiovascular Research Centre, Royal Brompton Hospital, UK;School of Biomedical Engineering \& Imaging Sciences, King's College London, UK;Yau Mathematical Sciences Center, Tsinghua University, CN

Peiyuan Jing, Chun-Wun Cheng, Liutao Yang, Zhenxuan Zhang, Thiago V. Lima, Klaus Strobel, Antoine Leimgruber, Angelica Aviles-Rivero, Guang Yang, Javier A. Montoya-Zegarra

AI总结:

MAP-Diff通过多锚点引导的扩散模型实现低剂量PET图像的渐进式去噪,提升PSNR和SSIM,降低NMAE,优于多种基线方法。

摘要:

低剂量正电子发射断层扫描(PET)减少了辐射暴露,但会遭受严重的噪声和定量退化。基于扩散的去噪模型能够实现强大的最终重建,但其反向轨迹通常不受约束,且不与PET剂量形成过程的渐进性质对齐。我们提出MAP-Diff,一种多锚点引导的扩散框架,用于渐进式三维全身PET去噪。MAP-Diff引入了临床观察到的中等剂量扫描作为轨迹锚点,并通过时间步依赖的监督来规范反向过程,使其朝着剂量对齐的中间状态发展。锚定时间步通过模拟扩散破坏与真实多剂量PET配对之间的退化匹配进行校准,并通过时间步加权锚点损失稳定阶段学习。在推理过程中,模型仅需超低剂量输入,同时能够实现渐进、剂量一致的中间恢复。在内部(西门子Biograph Vision Quadra)和跨扫描仪(联影uEXPLORER)数据集上的实验表明,与强大的CNN、Transformer、GAN和扩散基线相比,有持续的改进。在内部数据集上,MAP-Diff将PSNR从42.48 dB提高到43.71 dB(+1.23 dB),将SSIM提高到0.986,并将NMAE从0.115降低到0.103(-0.012),相比3D DDPM。性能提升在不同扫描仪上具有通用性,实现了34.42 dB PSNR和0.141 NMAE在外部队列上的表现,优于所有竞争方法。

英文摘要:

Low-dose Positron Emission Tomography (PET) reduces radiation exposure but suffers from severe noise and quantitative degradation. Diffusion-based denoising models achieve strong final reconstructions, yet their reverse trajectories are typically unconstrained and not aligned with the progressive nature of PET dose formation. We propose MAP-Diff, a multi-anchor guided diffusion framework for progressive 3D whole-body PET denoising. MAP-Diff introduces clinically observed intermediate-dose scans as trajectory anchors and enforces timestep-dependent supervision to regularize the reverse process toward dose-aligned intermediate states. Anchor timesteps are calibrated via degradation matching between simulated diffusion corruption and real multi-dose PET pairs, and a timestep-weighted anchor loss stabilizes stage-wise learning. At inference, the model requires only ultra-low-dose input while enabling progressive, dose-consistent intermediate restoration. Experiments on internal (Siemens Biograph Vision Quadra) and cross-scanner (United Imaging uEXPLORER) datasets show consistent improvements over strong CNN-, Transformer-, GAN-, and diffusion-based baselines. On the internal dataset, MAP-Diff improves PSNR from 42.48 dB to 43.71 dB (+1.23 dB), increases SSIM to 0.986, and reduces NMAE from 0.115 to 0.103 (-0.012) compared to 3D DDPM. Performance gains generalize across scanners, achieving 34.42 dB PSNR and 0.141 NMAE on the external cohort, outperforming all competing methods.