相位诱导振幅衰减复用复用冠状仪(PIAACMC)在MagAO-X上的天体观测演示

Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) on-sky demonstration with MagAO-X

Leiden University(莱顿大学);The University of Arizona(亚利桑那大学);National Observatory of Japan(日本国立天文台);National Institutes of Natural Sciences(自然科学研究機構);Northrop Grumman Corporation(诺斯罗普·格鲁曼公司)
Elena Tonucci, Sebastiaan Haffert, Warren Foster, Jared Males, Olivier Guyon, Laird M. Close, Kyle van Gorkom, Alexander Hedglen, Parker Johnson, Maggie Kautz, … 展开作者

Elena Tonucci, Sebastiaan Haffert, Warren Foster, Jared Males, Olivier Guyon, Laird M. Close, Kyle van Gorkom, Alexander Hedglen, Parker Johnson, Maggie Kautz, Jay Kueny, Jialin Li, Joshua Liberman, Joseph Long, Jennifer Lumbres, Matthijs Mars, Eden McEwen, Avalon McLeod, Logan Pearce, Lauren Schatz, Katie Twitchell

AI总结:

本文首次在天体观测中验证了PIAACMC的对比度和内工作角性能,展示了其在亚微米波长下的技术演示,主要贡献在于验证了其在高对比度成像中的潜力。

摘要:

推进小内工作角(IWA)冠状仪技术发展对于未来极大望远镜高对比度成像温带系外行星至关重要。PIAACMC已被证明接近冠状仪通过量的理论极限,但其性能尚未在天体观测中完全表征。本研究是首次对PIAACMC的对比度和IWA性能进行天体观测表征,并首次在亚微米波长下进行技术演示。我们设计并制造了优化于两种情况的相位移聚焦平面掩模,一种是窄带875滤光片(875nm,3%带宽)和一种是宽带z'滤光片(908nm,14%带宽)。我们使用MagAOX,即位于拉斯坎帕纳斯天文台的Magellan Clay 6.5米望远镜的极端自适应光学仪器,对冠状仪进行了内部光源和天体观测测试。我们展示了在对准PIAA透镜逆集时,偏轴光的PSF形状在92%和97%的分离度内良好恢复。我们演示了在875nm下约0.74lambda/D和z'下约0.76lambda/D的亚lambda/D IWA。我们达到内部光源下的平均原始对比度在1和5lambda/D内,875nm约为1.6e-3,z'约为1.3e-3。这些主要受限于聚焦平面掩模制造误差、抖动和MagAO-X中的残留准静态散斑。我们还展示了天体观测中平均原始对比度在1和5lambda/D内约为875nm的1.4e-2和z'的7.8e-3。这些可能受限于波前控制、低阶像差和较差的观测条件。未来工作将改进聚焦平面掩模的设计和制造工艺,以提高鲁棒性和达到更深层的对比度,同时整合聚焦平面波前控制以纠正非共同路径像差。

英文摘要:

Advancing the technological development of small inner working angle (IWA) coronagraphs is essential to enabling high-contrast imaging of temperate exoplanets with future extremely large telescopes. The PIAACMC has been shown to closely approach the theoretical limit for coronagraphic throughput but its performance has not been fully characterised on-sky. This study serves as the first on-sky characterisation of contrast and IWA performance of the PIAACMC and its first technological demonstration at sub-micron wavelengths. We designed and manufactured phase-shifting focal plane masks optimised for two cases, a narrowband 875 filter (875nm, 3% band) and a broadband z' filter (908nm, 14% band). We tested the coronagraphs both with an internal source and on-sky using MagAOX, the extreme adaptive optics instrument for the Magellan Clay 6.5 m telescope at Las Campanas Observatory. We show good recovery of the off-axis light's PSF shape within 92% and 97% depending on the separation when aligning the inverse set of PIAA lenses. We demonstrate sub-lambda/D IWAs of about 0.74 lambda/D in 875 and 0.76 lambda/D in z'. We reach average raw contrasts within 1 and 5 lambda/D with the internal source of about 1.6e-3 in 875 and 1.3e-3 in z'. These are mainly limited by the focal plane mask manufacturing errors, jitter, and residual quasi-static speckles in MagAO-X. We also show on-sky average raw contrasts within 1 and 5 lambda/D of about 1.4e-2 in 875 and 7.8e-3 in z'. These are likely limited by wavefront control, low-order aberrations, and poor observing conditions. Future work will improve the design and manufacturing processes of the focal plane masks to improve robustness and reach deeper contrast, as well as integrate focal plane wavefront control for non-common path aberrations correction.