利用Wasserstein度量的全波形反演用于基于超声换能器阵列的无损检测
Full Waveform Inversion using the Wasserstein metric for ultrasound transducer array based NDT
AI总结:
本文提出利用Wasserstein度量改进超声全波形反演,通过分析连续时间域的共轭声场推导梯度计算方法,采用低内存策略提升计算效率,实验显示W2误差点估计精度显著高于L2。
摘要:
超声成像方法通常假设线性直接模型,但现实中存在非线性现象,如多路径反射。全波形反演(FWI)通过全声波模拟考虑所有非线性,可提高成像精度。然而,FWI应用于超声数据时,由于缺乏低频成分,循环跳变问题加剧。本文探索将Wasserstein度量作为获取数据与合成数据之间的误配度量,应用于超声相控阵无损检测。推导了与W2误配相关的连续时间域共轭声场,并用于梯度计算。为应对FWI计算负担,采用低内存策略,无需存储完整模拟场。详细描述了CUDA实现,提供源代码。六个典型案例中,W2误配的像素平方误差比L2低一个数量级,梯度计算时间增加不超过2%。结果表明W2误配适用于超声FWI相控阵,且计算可行。
英文摘要:
Ultrasonic imaging methods often assume linear direct models, while in reality, many nonlinear phenomena are present, e.g. multiple reflections. A family of imaging methods called Full Waveform Inversion (FWI), which has been developed in the field of seismic imaging, uses full acoustic wave simulations as direct models, taking into account virtually all nonlinearities, which can ultimately enhance the accuracy of ultrasonic imaging. However, the problem of cycle skipping -- the existence of many local minima of the Least Squares (L2) misfit function due to the oscillatory nature of the signals -- is worsened when FWI is applied to ultrasound data because of a lack of low-frequency components. In this paper, we explore the use of the squared Wasserstein (W2) Optimal Transport Distance as the metric for the misfit between the acquired and the synthetic data, applying the method to Nondestructive Evaluation with ultrasonic phased arrays. An analytical continuous time-domain derivation of the adjoint acoustic field related to the W2 misfit is presented and used for the computation of the gradients. To cope with the computational burden of FWI, we apply a low-memory strategy that allows for the computation of the gradients without the storage of the full simulated fields. The GPU implementation of the method (in CUDA language) is detailed, and the source code is made available. Six prototypical cases are presented, and the corresponding sound speed maps are reconstructed with FWI using both the L2 and the W2 misfit functionals. In five of the six cases, the pixel-wise sum of squared errors obtained with W2 was at least one order of magnitude lower than that obtained with W2, with an increase in the gradient computation time not exceeding 2\%. The results highlight both the adequacy of the W2 misfit for ultrasonic FWI with phased arrays and its computational feasibility.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。