Spatial response identification enables robust experimental ultrasound computed tomography
摘要:
超声计算机断层扫描技术有可能为临床医生提供软组织和硬组织(如乳腺或成人大脑)的3D、定量和高分辨率信息。它们的实际应用需要采集设置的精确建模:每个超声换能器的空间位置、方向和脉冲响应。然而,现有的校准方法无法准确地校准这些换能器,除非它们的尺寸与主波长相比可以被认为是可忽略的,这在存在高对比度组织(例如颅骨)的情况下将信噪比降低到可用水平以下。在本文中,我们介绍了一种方法,可以同时估计的位置,方向和脉冲响应的超声换能器在一个单一的校准。我们这样做,通过扩展空间响应识别,我们最近提出的估计换能器脉冲响应的算法。我们提出的方法取代了传感器的采集设备与代理模型,其有效响应匹配的实验数据,通过拟合波传播的数值模型。这导致灵活且鲁棒的校准过程,其可以准确地预测超声采集设备的行为,而不必知道真实换能器在哪里或它们的个体脉冲响应。使用环采集系统的实验结果表明,空间响应识别产生的校准质量显着高于所有传感器的标准方法,无论是在传输和接收。实验全波形反演重建的组织模仿幻影表明,空间响应识别产生更准确的重建比标准校准技术产生的。
英文摘要:
Ultrasound computed tomography techniques have the potential to provide clinicians with 3D, quantitative and high-resolution information of both soft and hard tissues such as the breast or the adult human brain. Their practical application requires accurate modelling of the acquisition setup: the spatial location, orientation, and impulse response of each ultrasound transducer. However, existing calibration methods fail to accurately characterise these transducers unless their size can be considered negligible when compared to the dominant wavelength, which reduces signal-to-noise ratios below usable levels in the presence of high-contrast tissues such as the skull. In this paper, we introduce a methodology that can simultaneously estimate the location, orientation, and impulse response of the ultrasound transducers in a single calibration. We do this by extending spatial response identification, an algorithm that we have recently proposed to estimate transducer impulse responses. Our proposed methodology replaces the transducers in the acquisition device with a surrogate model whose effective response matches the experimental data by fitting a numerical model of wave propagation. This results in a flexible and robust calibration procedure that can accurately predict the behaviour of the ultrasound acquisition device without ever having to know where the real transducers are or their individual impulse response. Experimental results using a ring acquisition system show that spatial response identification produces calibrations of significantly higher quality than standard methodologies across all transducers, both in transmission and in reception. Experimental full-waveform inversion reconstructions of a tissue-mimicking phantom demonstrate that spatial response identification generates more accurate reconstructions than those produced with standard calibration techniques.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。