双自由度软肩外骨骼的设计与特性分析:体积优化的气动执行器
Design and Characterization of a Dual-DOF Soft Shoulder Exosuit with Volume-Optimized Pneumatic Actuator
AI总结:
本文提出了一种双自由度软肩外骨骼,通过体积优化的气动执行器设计,实现了高效的肩部运动辅助与肌电活动的显著降低。
摘要:
针对双自由度(DOF)软肩外骨骼的便携式气动系统仍处于探索阶段,其在扭矩输出与动态响应之间存在根本性权衡,且需要多个执行器以支持复杂的肩部运动。本文通过体积优化的 spindle-shaped angled actuator(SSAA)几何结构来解决这些限制:通过将执行器体积减少35.7%(357mL vs. 555mL),SSAA 保持了94.2%的输出扭矩,同时比均匀圆柱形设计快35.2%的动态响应。基于SSAA,我们开发了一种基于SSAA几何结构的曲线背离执行器(CAA)和基于囊状电机原理的水平加离执行器(HAA),并将两者集成到双自由度纺织肩外骨骼中(390克)。该外骨骼能够提供多模式辅助,涵盖肩部背离、屈曲和水平加离,取决于执行器的驱动。对10名健康受试者的用户研究发现,该外骨骼在肩部背离和屈曲任务中显著减少了肌电图(EMG)活动。对于仅使用HAA的背离任务,该外骨骼在七块肌肉中实现了高达59%的肌肉活动减少。对于屈曲,单执行器配置(仅HAA)和双执行器配置(HAA, CAA)在无辅助的情况下,屈曲的EMG活动分别减少了高达63.7%。然而,在健康受试者中,将CAA添加到现有HAA支持的增量效益在屈曲中有限,只有在胸大肌中观察到统计学上显著的额外减少。这些实验发现表征了健康受试者的执行器贡献,并为多自由度外骨骼系统提供了设计指导。
英文摘要:
Portable pneumatic systems for 2 degree-of-freedom (DOF) soft shoulder exosuits remain underexplored, and face fundamental trade-offs between torque output and dynamic response that are further compounded by the need for multiple actuators to support complex shoulder movement. This work addresses these constraints through a volume-optimized spindle-shaped angled actuator (SSAA) geometry: by reducing actuator volume by 35.7% (357mL vs. 555mL), the SSAA maintains 94.2% of output torque while achieving 35.2% faster dynamic response compared to uniform cylindrical designs. Building on the SSAA, we develop a curved abduction actuator (CAA) based on the SSAA geometry and a horizontal adduction actuator (HAA) based on the pouch motor principle, integrating both into a dual-DOF textile-based shoulder exosuit (390 g). The exosuit delivers multi-modal assistance spanning shoulder abduction, flexion, and horizontal adduction, depending on the actuation. User studies with 10 healthy participants reveal that the exosuit substantially reduces electromyographic (EMG) activity across both shoulder abduction and flexion tasks. For abduction with HAA only, the exosuit achieved up to 59% muscle activity reduction across seven muscles. For flexion, both the single-actuator configuration (HAA only) and the dual-actuator configuration (HAA,+,CAA) reduced EMG activity by up to 63.7% compared to no assistance. However, the incremental benefit of adding the CAA to existing HAA support was limited in healthy users during flexion, with statistically significant additional reductions observed only in pectoralis major. These experimental findings characterize actuator contributions in healthy users and provide design guidance for multi-DOF exosuit systems.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。