arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2403.04729cs.RO
收藏

用于外骨骼服中自适应低位移锚定的可伸缩气动套袖

Stretchable Pneumatic Sleeve for Adaptable, Low-Displacement Anchoring in Exosuits

University of Notre Dame(圣母大学);Pázmány Péter Catholic University(帕兹曼尼·彼得天主教大学);University of Galway(高威大学)

Katalin Schaffer, Ultan Fallon, Margaret M. Coad

AI总结:

本文提出一种由织物气动人工肌肉带构成的可伸缩气动套袖,用于外骨骼服在手臂上的低位移自适应锚定,实验证明其性能与SPM套袖相当且耐压更高、未充气时也能提供锚定。

摘要:

尽管可穿戴技术近年来取得了进展,但将运动辅助设备与人体连接仍然具有挑战性。我们提出了一种可伸缩气动套袖,它能够将外骨骼服执行器锚定在人体手臂上,并且在操作过程中执行器安装点相对于身体的位移很小。我们的套袖有潜力作为外骨骼服的自适应附着机构,因为它可以调节其压力,仅根据需要压缩手臂以传递所施加的外骨骼服力,而不会产生较大位移。我们讨论了套袖的设计,该套袖由织物气动人工肌肉(fPAM)执行器制成带状。我们通过测量压缩力随压力的变化,以及可抵抗的局部拉力随压力和安装点位移的变化,量化了九种不同长度和宽度的fPAM带的性能,以及三种套袖(一种fPAM套袖、一种如先前文献中的串联袋式马达(SPM)套袖,以及一种现成的钩环套袖)的性能。我们的实验结果表明,具有较小静止长度和/或较大静止宽度的fPAM带会产生更高的力。此外,当充气时,一个在完全拉伸状态下与SPM套袖具有相同尺寸的fPAM套袖,其性能与SPM套袖相似。在充气状态下,两种气动套袖与钩环套袖相比都减小了安装点位移。与SPM套袖相比,fPAM套袖能够在爆裂前承受更大的内部压力,从而增加了其可能的力范围。此外,在未充气时,fPAM套袖能很好地抵抗拉力,表明其能够在未驱动时提供锚定能力。

英文摘要:

Despite recent advances in wearable technology, interfacing movement assistance devices with the human body remains challenging. We present a stretchable pneumatic sleeve that can anchor an exosuit actuator to the human arm with a low displacement of the actuator's mounting point relative to the body during operation. Our sleeve has the potential to serve as an adaptable attachment mechanism for exosuits, since it can adjust its pressure to only compress the arm as much as needed to transmit the applied exosuit forces without a large displacement. We discuss the design of our sleeve, which is made of fabric pneumatic artificial muscle (fPAM) actuators formed into bands. We quantify the performance of nine fPAM bands of various lengths and widths, as well as three sleeves (an fPAM sleeve, a series pouch motor (SPM) sleeve as in previous literature, and an off the shelf hook and loop sleeve), through the measurement of the compressing force as a function of pressure and the localized pulling force that can be resisted as a function of both pressure and mounting point displacement. Our experimental results show that fPAM bands with smaller resting length and/or larger resting width produce higher forces. Also, when inflated, an fPAM sleeve that has equivalent dimensions to the SPM sleeve while fully stretched has similar performance to the SPM sleeve. While inflated, both pneumatic sleeves decrease the mounting point displacement compared to the hook and loop sleeve. Compared to the SPM sleeve, the fPAM sleeve is able to hold larger internal pressure before bursting, increasing its possible force range. Also, when not inflated, the fPAM sleeve resists the pulling force well, indicating its ability to provide anchoring when not actuated.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑