In critical decision support systems based on medical imaging, the reliability of AI-assisted decision-making is as relevant as predictive accuracy. Although deep learning models have demonstrated significant accuracy, they frequently suffer from miscalibration, manifested as overconfidence in erroneous predictions. To facilitate clinical acceptance, it is imperative that models quantify uncertainty in a manner that correlates with prediction correctness, allowing clinicians to identify unreliable outputs for further review. To address this necessity, this paper proposes a probabilistic optimization framework grounded in Bayesian deep learning. Specifically, the Confidence-Uncertainty Boundary Curve (CUBC) is first explored as an intermediate operational target. Grounded in this target, a novel Confidence-Uncertainty Boundary Loss (CUB-Loss) is proposed to regularize the alignment between prediction confidence and uncertainty estimates during training, imposing penalties on high-certainty errors and low-certainty correct predictions. Upon completion of training optimization, a Boundary Curve Calibration Error (BCCE) metric is further introduced to measure the degree of boundary alignment in the calibrated model. Building on this measurement, a Dual Temperature Scaling (DTS) strategy is devised to perform post-hoc refinement, further adjusting the posterior predictive distribution across different confidence-uncertainty regions. The proposed framework is validated on three distinct medical imaging tasks: automatic screening of pneumonia, diabetic retinopathy detection, and identification of skin lesions. Empirical results demonstrate that the proposed approach improves uncertainty calibration across diverse modalities, maintains robust performance in data-scarce scenarios, and remains effective on severely imbalanced datasets, underscoring its potential for real clinical deployment.
Overconfidence and Calibration in Medical VQA: Empirical Findings and Hallucination-Aware Mitigation
Johns Hopkins University, School of Medicine(约翰霍普金斯大学医学院);Massachusetts Institute of Technology(麻省理工学院);Microsoft Healthcare & Life Sciences(微软医疗健康与生命科学)
Does confidence calibration improve conformal prediction?
Southern University of Science and Technology(南方科技大学);Nanyang Technological University(南洋理工大学);University of Macau(澳门大学);Singapore University of Technology and Design(新加坡科技设计大学)
DOMINO: Domain-aware Model Calibration in Medical Image Segmentation
University of Florida(佛罗里达大学);Herbert Wertheim College of Engineering(赫伯特·韦特海姆工程学院);McKnight Brain Institute(麦克奈特脑研究所);College of Public Health and Health Professions(公共卫生与健康职业学院);College of Medicine(医学院);United States Air Force Research Laboratory(美国空军研究实验室)
Exposing and Mitigating Calibration Biases and Demographic Unfairness in MLLM Few-Shot In-Context Learning for Medical Image Classification
Centre for Intelligent Machines, McGill University, Montreal, Canada(智能机器中心,麦吉尔大学,加拿大);Mila -- Quebec AI Institute, Montreal, Canada(魁北克人工智能研究所);Stanford University, Stanford, USA(斯坦福大学);University of Copenhagen, Copenhagen, Denmark(哥本哈根大学)
Impact of Data Augmentation on Confidence Calibration in Melanoma Classification
Technological University Dublin(都柏林理工大学);Research Ireland Centre for Research Training in Machine Learning(爱尔兰研究机器学习研究培训中心);University College Dublin(都柏林大学学院);Dublin City University(都柏林城市大学)
Dual-View Pyramid Pooling in Deep Neural Networks for Improved Medical Image Classification and Confidence Calibration
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院);Southern University of Science and Technology(南方科技大学);The University of Hong Kong(香港大学);Zhengzhou University(郑州大学);Central South University(中南大学);Xinjiang University(新疆大学)
Deep Neural Network Calibration by Reducing Classifier Shift with Stochastic Masking
School of Artificial Intelligence, Jilin University(吉林大学人工智能学院);CSIRO's Data61 and Monash University (adjunct)(CSIRO的数据61与墨尔本大学(兼职));King Abdullah University of Science and Technology(国王阿卜杜勒阿齐兹科技大学)
Prototype-Enhanced Confidence Modeling for Cross-Modal Medical Image-Report Retrieval
School of Computer Science, The University of Nottingham, NG8 1BB Nottingham, U.K.(计算机科学学院,诺丁汉大学);Department of Intelligent Science, Xi’an Jiaotong-Liverpool University, China, 215123.(智能科学系,西安交通大学利物浦大学)
Calibrating Bayesian Learning via Regularization, Confidence Minimization, and Selective Inference
King’s Communications, Learning & Information Processing (KCLIP) lab(国王通讯、学习与信息处理(KCLIP)实验室);Centre for Intelligent Information Processing Systems (CIIPS)(智能信息处理系统中心);Department of Engineering, King’s College London(伦敦国王学院工程系)
CAD: Confidence-Aware Adaptive Displacement for Semi-Supervised Medical Image Segmentation
College of Information and Intelligence, Hunan Agricultural University(湖南农业大学信息与智能科学学院);School of Computer Science and Engineering, University of New South Wales(新南威尔士大学计算机科学与工程学院)
MVC-Bench: Benchmarking Calibration of Medical Vision-Language Models
Mohamed bin Zayed University of AI(穆罕默德·本·扎耶德人工智能大学);Sabaragamuwa University of Sri Lanka(斯里兰卡萨巴拉加穆瓦大学);Digital Platform Development, SLT PLC(SLT公共有限公司数字平台开发部)