arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.11973cs.CVcs.LG
收藏

医学图像分析中贝叶斯深度学习的置信-不确定性边界校准

Confidence-Uncertainty Boundary Calibration for Bayesian Deep Learning in Medical Image Analysis

Escuela Técnica Superior de Ingenieros de Telecomunicación Universidad Politécnica de Madrid(电信工程高级学院马德里理工大学)

Hua Xu, Julián D. Arias-Londoño, Juan I. Godino-Llorente

AI总结:

提出基于贝叶斯深度学习的概率优化框架,通过置信-不确定性边界曲线(CUBC)和边界损失(CUB-Loss)校准预测置信与不确定性,并引入双温度缩放(DTS)进行后处理,在肺炎、糖尿病视网膜病变和皮肤病变三个医学图像任务上验证了有效性。

摘要:

在基于医学影像的关键决策支持系统中,AI辅助决策的可靠性与预测准确性同等重要。尽管深度学习模型已展现出显著的准确性,但它们经常遭受校准不良的问题,表现为对错误预测的过度自信。为促进临床接受,模型必须以与预测正确性相关的方式量化不确定性,使临床医生能够识别不可靠的输出以进行进一步审查。为满足这一需求,本文提出了一种基于贝叶斯深度学习的概率优化框架。具体而言,首先探索置信-不确定性边界曲线(CUBC)作为中间操作目标。基于该目标,提出了一种新颖的置信-不确定性边界损失(CUB-Loss),用于在训练过程中正则化预测置信度与不确定性估计之间的对齐,对高置信度错误和低置信度正确预测施加惩罚。完成训练优化后,进一步引入边界曲线校准误差(BCCE)指标来衡量校准模型中边界对齐的程度。基于该度量,设计了一种双温度缩放(DTS)策略进行后处理细化,进一步调整不同置信-不确定性区域的后验预测分布。所提出的框架在三个不同的医学成像任务上进行了验证:肺炎自动筛查、糖尿病视网膜病变检测和皮肤病变识别。实验结果表明,该方法改善了跨不同模态的不确定性校准,在数据稀缺场景下保持稳健性能,并在严重不平衡数据集上仍然有效,突显了其在真实临床部署中的潜力。

英文摘要:

In critical decision support systems based on medical imaging, the reliability of AI-assisted decision-making is as relevant as predictive accuracy. Although deep learning models have demonstrated significant accuracy, they frequently suffer from miscalibration, manifested as overconfidence in erroneous predictions. To facilitate clinical acceptance, it is imperative that models quantify uncertainty in a manner that correlates with prediction correctness, allowing clinicians to identify unreliable outputs for further review. To address this necessity, this paper proposes a probabilistic optimization framework grounded in Bayesian deep learning. Specifically, the Confidence-Uncertainty Boundary Curve (CUBC) is first explored as an intermediate operational target. Grounded in this target, a novel Confidence-Uncertainty Boundary Loss (CUB-Loss) is proposed to regularize the alignment between prediction confidence and uncertainty estimates during training, imposing penalties on high-certainty errors and low-certainty correct predictions. Upon completion of training optimization, a Boundary Curve Calibration Error (BCCE) metric is further introduced to measure the degree of boundary alignment in the calibrated model. Building on this measurement, a Dual Temperature Scaling (DTS) strategy is devised to perform post-hoc refinement, further adjusting the posterior predictive distribution across different confidence-uncertainty regions. The proposed framework is validated on three distinct medical imaging tasks: automatic screening of pneumonia, diabetic retinopathy detection, and identification of skin lesions. Empirical results demonstrate that the proposed approach improves uncertainty calibration across diverse modalities, maintains robust performance in data-scarce scenarios, and remains effective on severely imbalanced datasets, underscoring its potential for real clinical deployment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑