理解微加工纳米热计的性能及其对低温等离子体放电能量通量的响应
Understanding microfabricated nanocalorimeter performance and responses to the energy fluxes from low-temperature plasma discharges
AI总结:
本研究提出了一种新型纳米热计,用于快速检测低温等离子体放电中的低能能量通量,并通过实验验证其高灵敏度和快速响应特性。
摘要:
等离子体诊断在快速和敏感的热计传感器方面存在不足,这些传感器能够跟踪等离子体辅助微加工过程中基板的温度。在本工作中,使用了一种新型的纳米热计传感器来探测氩气和氧气射频(RF) glow放电产生的能量通量。该探针由超薄的SiNx膜(100 nm)和经光刻定义的Pt微带(100 nm)组成,后者作为校准的电阻热计。当暴露于射频等离子体时,探针温度可在一秒内从室温升高到几百度,这取决于实验的几何形状和等离子体参数。这种灵敏度和响应时间是由于预设计的减少的热容量和显著减少的冷却通道热导率。这些特性使得该传感器能够灵敏地检测表面上的低能等离子体通量,并通过在传感器上施加负或正电势来快速区分,如离子和电子通量的情况。这些施加的纳米热计能量读数已与通过Langmuir探针和减速场能量分析仪(RFEA)评估的离子和电子动能耗散进行了比较。最后,讨论了等离子体纳米热计的鲁棒性,包括其基线漂移、退化和寿命。
英文摘要:
Plasma diagnostics have a shortage of fast and sensitive calorimetric sensors that can track substrate temperature during plasma-assisted microfabrication. In this work, energy fluxes from argon and oxygen radiofrequency (RF) glow discharges have been probed using a novel nanocalorimeter sensor. The probe consists of an ultrathin SiNx membrane (100 nm) with a lithographically defined Pt micro-strip (100 nm) that serves as a calibrated resistance thermometer. The sensor temperature can increase from room temperature to several hundred degrees within a second upon exposure to RF plasma, depending on the experiment's geometry and plasma parameters. Such sensitivity and response time are due to the pre-designed reduced heat capacity of the sensor and significantly reduced thermal conductance of the cooling channels. These features enable the sensitive detection of low-energy plasma fluxes on surfaces and their rapid discrimination, as in the case of ion and electron fluxes, by biasing the sensor at negative or positive potentials. These biased nanocalorimeter energy readings have been compared with ion and electron kinetic energy dissipations assessed using a Langmuir probe and retarding field energy analyzer (RFEA). Finally, the robustness of the plasma nanocalorimeter is discussed in terms of its baseline drifts, degradation, and longevity.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。