arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2512.09220astro-ph.HEastro-ph.IM
收藏

毫秒脉冲星的频率和相位解析偏振测量及其在定时中的应用

Frequency- and phase-resolved polarimetry of millisecond pulsars and its application to timing

Monash University(莫纳什大学);OzGrav: The ARC Centre of Excellence for Gravitational Wave Discovery(ARC引力波发现卓越中心);Australia Telescope National Facility, CSIRO(澳大利亚国家望远镜设施,CSIRO);Xinjiang Astronomical Observatory, Chinese Academy of Sciences(中国科学院新疆天文台);Max Planck Institute for Gravitational Physics (Albert Einstein Institute)(马克斯·普朗克引力物理学研究所(爱因斯坦研究所));Leibniz Universität Hannover(汉诺威莱布尼茨大学);Hunan Normal University(湖南师范大学)
Małgorzata Curyło, Andrew Zic, Shuangqiang Wang, Eric Thrane, Paul D. Lasky, Jacob Cardinal Tremblay, Zu-Cheng Chen, Shi Dai, Valentina Di Marco, George Hobbs, … 展开作者

Małgorzata Curyło, Andrew Zic, Shuangqiang Wang, Eric Thrane, Paul D. Lasky, Jacob Cardinal Tremblay, Zu-Cheng Chen, Shi Dai, Valentina Di Marco, George Hobbs, Agastya Kapur, Wenhua Ling, Marcus E. Lower, Rami F. Mandow, Saurav Mishra, Daniel J. Reardon, Christopher J. Russell, Ryan M. Shannon, Xing-Jiang Zhu

AI总结:

本文提出一种新方法,利用极化信息生成高保真模板,提高脉冲到达时间测量精度。该方法通过分析四个斯托克斯参数的频率依赖模型,减少定时测量误差达20-30%。

摘要:

脉冲星定时被用于测试基本物理、探测中子星结构和检测纳赫兹引力波。本文提出一种新方法,利用所有可用极化信息生成频率依赖的脉冲形状演变模型,从而提高脉冲到达时间测量的精度。我们的框架利用所有可用的极化信息来生成四个斯托克斯参数的频率依赖模型。我们应用该方法于帕克斯脉冲星定时阵列观测的毫秒脉冲星,并证明其结果将定时测量误差减少到约20-30%。我们还首次展示了使用帕克斯穆里扬超宽带低接收机观测的毫秒脉冲星的相位和频率解析极化测量。数据、图表和分析代码已公开发布。

英文摘要:

Pulsar timing is used for a variety of applications including tests of fundamental physics, probing the structure of neutron stars, and detecting nanohertz gravitational waves. Development of robust methods and generation of high-quality timing data is therefore of utmost importance. In this paper, we present a new technique for creating high-fidelity templates that can be used to measure the pulse times of arrival with significantly increased precision compared to existing methods. Our framework makes use of all available polarimetric information to generate frequency-dependent models of pulse-shape evolution of all four Stokes parameters. We apply this method to millisecond pulsars observed by the Parkes Pulsar Timing Array and show that it results in timing measurement uncertainties reduced up to $\sim$20-30%. We also present, for the first time, phase- and frequency-resolved polarimetric measurements of millisecond pulsars observed with the Parkes Murriyang ultra-widebandwith-low receiver. The data, plots and the code underlying this analysis are made publicly available.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑