arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2512.01534cs.CVcs.AI
收藏

深度无监督脑影像异常检测:大规模基准测试与偏差分析

Deep Unsupervised Anomaly Detection in Brain Imaging: Large-Scale Benchmarking and Bias Analysis

Department of Psychiatry and Psychotherapy, University Hospital Tübingen(图宾根大学精神病学与心理学系);Cluster of Excellence – Machine Learning for Science, University of Tübingen(图宾根大学机器学习科学卓越中心);Department of Psychology, Friedrich Schiller University of Jena(耶拿弗里德里希·席勒大学心理学系);German Center for Mental Health (DZPG), partner site Halle/Jena/Magdeburg(德国心理健康中心(DZPG)哈勒/耶拿/马格德堡分部);University of Lucerne(卢塞恩大学)

Alexander Frotscher, Christian F. Baumgartner, Thomas Wolfers

AI总结:

本文提出大规模脑影像无监督异常检测基准测试,揭示了算法间显著差异及系统性偏差,强调了算法改进对临床应用的重要性。

摘要:

深度无监督异常检测在脑部磁共振成像中提供了一条有前景的途径,用于在不需特定病变标注的情况下识别病理偏离。然而,碎片化的评估、异质的数据集和不一致的指标阻碍了其向临床应用的转化。本文提出了一项大规模、多中心的深度无监督脑影像异常检测基准测试。训练集包含来自六个不同设备的2976例T1和2972例T2加权扫描,年龄范围为6至89岁。验证阶段使用92例扫描调整超参数并估计无偏阈值。测试阶段涵盖2221例T1w和1262例T2w扫描,覆盖健康数据集和多样化的临床群体。所有算法的Dice分割性能在0.03至0.65之间变化,表明存在显著差异。为评估鲁棒性,我们系统评估了不同设备、病变类型和大小以及人口统计学因素(年龄、性别)的影响。基于重建的方法,特别是扩散启发式方法,在病变分割性能上表现最强,而基于特征的方法在分布偏移下更具鲁棒性。然而,系统性偏差,如设备相关影响,在大多数算法中被观察到,包括小而低对比度的病变更容易被遗漏,以及假阳性随年龄和性别变化。增加健康训练数据带来的收益有限,这表明当前无监督异常检测框架的限制在于算法而非数据可用性。我们的基准测试为未来研究建立了透明的基础,并突出了临床应用中的优先事项,包括图像原生预训练、原理性偏离度量、公平性感知建模和鲁棒域适应。

英文摘要:

Deep unsupervised anomaly detection in brain magnetic resonance imaging offers a promising route to identify pathological deviations without requiring lesion-specific annotations. Yet, fragmented evaluations, heterogeneous datasets, and inconsistent metrics have hindered progress toward clinical translation. Here, we present a large-scale, multi-center benchmark of deep unsupervised anomaly detection for brain imaging. The training cohort comprised 2,976 T1 and 2,972 T2-weighted scans from healthy individuals across six scanners, with ages ranging from 6 to 89 years. Validation used 92 scans to tune hyperparameters and estimate unbiased thresholds. Testing encompassed 2,221 T1w and 1,262 T2w scans spanning healthy datasets and diverse clinical cohorts. Across all algorithms, the Dice-based segmentation performance varied between 0.03 and 0.65, indicating substantial variability. To assess robustness, we systematically evaluated the impact of different scanners, lesion types and sizes, as well as demographics (age, sex). Reconstruction-based methods, particularly diffusion-inspired approaches, achieved the strongest lesion segmentation performance, while feature-based methods showed greater robustness under distributional shifts. However, systematic biases, such as scanner-related effects, were observed for the majority of algorithms, including that small and low-contrast lesions were missed more often, and that false positives varied with age and sex. Increasing healthy training data yields only modest gains, underscoring that current unsupervised anomaly detection frameworks are limited algorithmically rather than by data availability. Our benchmark establishes a transparent foundation for future research and highlights priorities for clinical translation, including image native pretraining, principled deviation measures, fairness-aware modeling, and robust domain adaptation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑