We conduct an extensive study on the state of calibration under real-world dataset shift for image classification. Our work provides important insights on the choice of post-hoc and in-training calibration techniques, and yields practical guidelines for all practitioners interested in robust calibration under shift. We compare various post-hoc calibration methods, and their interactions with common in-training calibration strategies (e.g., label smoothing), across a wide range of natural shifts, on eight different classification tasks across several imaging domains. We find that: (i) simultaneously applying entropy regularisation and label smoothing yield the best calibrated raw probabilities under dataset shift, (ii) post-hoc calibrators exposed to a small amount of semantic out-of-distribution data (unrelated to the task) are most robust under shift, (iii) recent calibration methods specifically aimed at increasing calibration under shifts do not necessarily offer significant improvements over simpler post-hoc calibration methods, (iv) improving calibration under shifts often comes at the cost of worsening in-distribution calibration. Importantly, these findings hold for randomly initialised classifiers, as well as for those finetuned from foundation models, the latter being consistently better calibrated compared to models trained from scratch. Finally, we conduct an in-depth analysis of ensembling effects, finding that (i) applying calibration prior to ensembling (instead of after) is more effective for calibration under shifts, (ii) for ensembles, OOD exposure deteriorates the ID-shifted calibration trade-off, (iii) ensembling remains one of the most effective methods to improve calibration robustness and, combined with finetuning from foundation models, yields best calibration results overall.
Towards Improving Calibration in Object Detection Under Domain Shift
Information Technology University of Punjab(旁遮普信息技术大学);Mohamed bin Zayed University of Artificial Intelligence(穆罕默德·本·扎耶德人工智能大学);Karlsruhe Institute of Technology(卡尔斯鲁厄理工学院);Mercedes-Benz Tech Innovation(梅赛德斯-奔驰技术创新公司)
Exposing and Mitigating Calibration Biases and Demographic Unfairness in MLLM Few-Shot In-Context Learning for Medical Image Classification
Centre for Intelligent Machines, McGill University, Montreal, Canada(智能机器中心,麦吉尔大学,加拿大);Mila -- Quebec AI Institute, Montreal, Canada(魁北克人工智能研究所);Stanford University, Stanford, USA(斯坦福大学);University of Copenhagen, Copenhagen, Denmark(哥本哈根大学)
Impact of Data Augmentation on Confidence Calibration in Melanoma Classification
Technological University Dublin(都柏林理工大学);Research Ireland Centre for Research Training in Machine Learning(爱尔兰研究机器学习研究培训中心);University College Dublin(都柏林大学学院);Dublin City University(都柏林城市大学)
Classification Calibration for Long-tail Instance Segmentation
National University of Singapore(新加坡国立大学);Institute of Computing Technology, Chinese Academy of Sciences(中国科学院计算技术研究所);Salesforce Research Asia(Salesforce亚洲研究院)
Learning Muti-expert Distribution Calibration for Long-tailed Video Classification
University of Science and Technology Beijing(北京科技大学);Peng Cheng Laboratory(鹏城实验室);Institute of Automation, Chinese Academy of Sciences(中国科学院自动化研究所);University of Chinese Academy of Sciences(中国科学院大学)
MVC-Bench: Benchmarking Calibration of Medical Vision-Language Models
Mohamed bin Zayed University of AI(穆罕默德·本·扎耶德人工智能大学);Sabaragamuwa University of Sri Lanka(斯里兰卡萨巴拉加穆瓦大学);Digital Platform Development, SLT PLC(SLT公共有限公司数字平台开发部)
Dual-View Pyramid Pooling in Deep Neural Networks for Improved Medical Image Classification and Confidence Calibration
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院);Southern University of Science and Technology(南方科技大学);The University of Hong Kong(香港大学);Zhengzhou University(郑州大学);Central South University(中南大学);Xinjiang University(新疆大学)
Expert Knowledge-Guided Decision Calibration for Accurate Fine-Grained Tree Species Classification
State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University(武汉大学测绘遥感信息工程国家重点实验室);Hubei Luojia Laboratory(湖北珞珈实验室)
Beyond Accuracy: Assessing Calibration of Geospatial Foundation Models and Their Sensitivity to Distribution Shifts
Technical University of Munich (TUM)(慕尼黑工业大学);German Aerospace Center (DLR)(德国航空航天中心);Massachusetts Institute of Technology (MIT)(麻省理工学院);Taylor Geospatial(泰勒地理空间公司)
Brain Tumor Classification using Vision Transformer with Selective Cross-Attention Mechanism and Feature Calibration
K.N. Toosi University of Technology(霍梅尼国际大学(K.N. Toosi理工大学));Indiana University-Purdue University(印第安纳大学-普渡大学);Shahed university(沙希德大学);University of Cincinnati(辛辛那提大学)
Uncertainty Aware Training to Improve Deep Learning Model Calibration for Classification of Cardiac MR Images
School of Biomedical Engineering & Imaging Sciences, King’s College London(伦敦国王学院生物医学工程与影像科学学院);Guy's and St Thomas' Hospital(盖伊和圣托马斯医院);BioMedIA Group, Department of Computing, Imperial College London(帝国理工学院计算系生物医学图像分析组)