基于实时仿真反馈的BESS多目标非线性功率分配控制
Multi-Objective Nonlinear Power Split Control For BESS With Real-Time Simulation Feedback
AI总结:
本文提出一种混合整数非线性多目标优化策略,结合电热联合仿真实时反馈SOC与温度,在保证功率可用性的前提下对逆变器与电池损耗进行Pareto权衡,实现BESS并联电池串的高效可靠功率分配。
摘要:
本文提出了一种混合整数、非线性、多目标优化策略,用于电池储能系统(BESS)中并联电池串之间的最优功率分配。通过将优化器与BESS电热仿真进行联合仿真,实现了高保真控制;该电热仿真对电池的空间热动态进行建模,提供实时的荷电状态(SOC)和温度反馈。优化器将功率可用性作为硬约束,并对电池热降额进行惩罚,从而优先保证可靠性。在这些约束范围内,控制器对逆变器损耗和电池损耗的相对权重进行Pareto扫描,以平衡逆变器效率与电池效率之间的权衡。逆变器损耗模型基于从商用逆变器系统获得的经验查找表(LUT),而电池热损耗模型使用与SOC和温度相关的内阻,电流由电池等效电路模型(ECM)计算得出。将该优化应用于双电池串BESS时,观察到逆变器损耗和电池损耗对系统可用性和热降额的竞争性影响。均衡运行使电池效率提高1%,逆变器效率提高1.5%,降额效率提高2%,同时保持更高的可用性。此外,BESS峰值温度降低5摄氏度也表明在不牺牲可用性的情况下降低了热应力。
英文摘要:
This paper presents a mixed-integer, nonlinear, multi-objective optimization strategy for optimal power allocation among parallel strings in Battery Energy Storage Systems (BESS). High-fidelity control is achieved by co-simulating the optimizer with a BESS electro-thermal simulation that models spatial thermal dynamics of the battery, providing real-time State of Charge (SOC) and temperature feedback. The optimizer prioritizes reliability by enforcing power availability as a hard constraint and penalizing battery thermal derating. Within these bounds, the controller performs a Pareto sweep on the relative weights of inverter and battery losses to balance the trade-off between inverter efficiency and battery efficiency. The inverter loss model is based on an empirical lookup table (LUT) derived from a commercial inverter system, while the battery thermal loss model uses SOC and temperature-dependent internal resistance, with electric current computed from the battery Equivalent Circuit Model (ECM). When the optimization was applied to a two-string BESS, the competing effects of inverter and battery losses on system availability and thermal derating were observed. The balanced operation yielded improvements of 1% in battery efficiency, 1.5% in inverter efficiency, and 2% in derating efficiency, while maintaining higher availability. Additionally, a 5 degrees C reduction in BESS peak temperature also suggests reduced thermal stress without compromising availability.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。