从既往MRI扫描中深度学习个性化先验,实现低成本系统的快速、质量增强型床旁MRI

Deep learning of personalized priors from past MRI scans enables fast, quality-enhanced point-of-care MRI with low-cost systems

Department of Electrical and Computer Engineering(电气与计算机工程系);Technion – Israel Institute of Technology(技术ion – 以色列理工学院);May-Blum-Dahl Technion Human MRI Research Center(技术ion 人类MRI研究中心);Department of Radiology(放射学系);C.J. Gorter MRI Center, Leiden University Medical Center(C.J. Gorter MRI中心,莱顿大学医学中心);Massachusetts General Hospital and Harvard Medical School(麻省总医院和哈佛医学院);Department of Biomedical Engineering(生物医学工程系)

Tal Oved, Beatrice Lena, Chloé F. Najac, Sheng Shen, Matthew S. Rosen, Andrew Webb, Efrat Shimron

AI总结:

本文提出利用深度学习从既往高场MRI扫描中提取个性化先验,通过ViT-Fuser特征融合视觉Transformer实现低成本低场MRI的加速与质量增强,并在多个数据集上验证其优于现有方法。

摘要:

磁共振成像(MRI)能提供卓越质量的图像,但其可及性受限于高昂成本,给需要长期随访的患者带来挑战。低场MRI以低成本设备提供经济实惠的成像,但受制于扫描时间长和图像质量下降,包括低信噪比(SNR)和组织对比度不足。我们提出一种新的医疗范式:利用深度学习从既往标准高场MRI扫描中提取个性化特征,并利用这些特征在低成本系统上实现加速、质量增强的随访扫描。为克服SNR和对比度差异,我们引入ViT-Fuser,一种特征融合视觉Transformer,它从既往扫描中学习特征,例如存储在标准DICOM光盘中的扫描。我们证明,单个既往扫描即已足够,且该扫描可来自不同MRI厂商、场强和脉冲序列。在四个数据集上的实验,包括胶质母细胞瘤数据、低场(50mT)和超低场(6.5mT)数据,表明ViT-Fuser优于最先进方法,能从加速低场扫描中提供质量增强的图像,并对分布外数据具有鲁棒性。因此,我们免费提供的框架能够为广泛的医疗应用实现快速、诊断质量、低成本的成像。

英文摘要:

Magnetic resonance imaging (MRI) offers superb-quality images, but its accessibility is limited by high costs, posing challenges for patients requiring longitudinal care. Low-field MRI provides affordable imaging with low-cost devices but is hindered by long scans and degraded image quality, including low signal-to-noise ratio (SNR) and tissue contrast. We propose a novel healthcare paradigm: using deep learning to extract personalized features from past standard high-field MRI scans and harnessing them to enable accelerated, enhanced-quality follow-up scans with low-cost systems. To overcome the SNR and contrast differences, we introduce ViT-Fuser, a feature-fusion vision transformer that learns features from past scans, e.g. those stored in standard DICOM CDs. We show that \textit{a single prior scan is sufficient}, and this scan can come from various MRI vendors, field strengths, and pulse sequences. Experiments with four datasets, including glioblastoma data, low-field ($50mT$), and ultra-low-field ($6.5mT$) data, demonstrate that ViT-Fuser outperforms state-of-the-art methods, providing enhanced-quality images from accelerated low-field scans, with robustness to out-of-distribution data. Our freely available framework thus enables rapid, diagnostic-quality, low-cost imaging for wide healthcare applications.