Estimating Blood Pressure with a Camera: An Exploratory Study of Ambulatory Patients with Cardiovascular Disease
University of Washington School of Medicine(华盛顿大学医学院);Paul G. Allen School of Computer Science & Engineering(保罗·G·艾伦计算机科学与工程学院);National and Kapodistrian University of Athens(雅典国立与卡波迪斯特里亚大学)
Theodore Curran, Chengqian Ma, Xin Liu, Daniel McDuff, Girish Narayanswamy, George Stergiou, Shwetak Patel, Eugene Yang
高血压是全球发病率和死亡率的主要原因。在门诊人群中对高血压进行诊断和治疗的能力,受到当前血压(BP)监测方法(特别是基于袖带的设备)可及性有限和依从性差的阻碍。远程光电容积脉搏波描记法(rPPG)通过标准摄像头且无需物理接触即可评估个体的脉搏波形。通过智能手机等嵌入式技术,全球大部分人口都能轻易获得摄像头,因此rPPG是一种可扩展且有前景的无创血压监测方法。少数研究rPPG用于血压测量的研究排除了高危人群,包括患有心血管疾病(CVD)或其风险因素的人群,以及处于活动性心律失常状态下的受试者。心律失常(如心房颤动)对使用rPPG预测血压的影响目前尚不确定。我们进行了一项研究,以更好地了解在来自心脏病诊所、已确诊CVD或具有CVD风险因素的真实世界门诊患者样本中,rPPG与血压之间的关系。我们在143名受试者静息时收集了同步的rPPG、PPG、血压、ECG及其他生命体征数据,并使用这些数据加上人口统计学信息来训练深度学习模型以预测血压。我们报告称,面部rPPG产生的信号与手指PPG相当。在该队列中,基于脉搏波分析(PWA)的血压估计表现与针对更健康受试者的研究相当,值得注意的是,心房颤动受试者的血压预测准确性并不劣于正常窦性心律受试者。在二元分类任务中,rPPG模型识别收缩压$\geq$ 130 mm Hg受试者的阳性预测值为71%(基线患病率为48.3%),突显了rPPG用于高血压监测的潜力。
英文摘要:
Hypertension is a leading cause of morbidity and mortality worldwide. The ability to diagnose and treat hypertension in the ambulatory population is hindered by limited access and poor adherence to current methods of monitoring blood pressure (BP), specifically, cuff-based devices. Remote photoplethysmography (rPPG) evaluates an individual's pulse waveform through a standard camera without physical contact. Cameras are readily available to the majority of the global population via embedded technologies such as smartphones, thus rPPG is a scalable and promising non-invasive method of BP monitoring. The few studies investigating rPPG for BP measurement have excluded high-risk populations, including those with cardiovascular disease (CVD) or its risk factors, as well as subjects in active cardiac arrhythmia. The impact of arrhythmia, like atrial fibrillation, on the prediction of BP using rPPG is currently uncertain. We performed a study to better understand the relationship between rPPG and BP in a real-world sample of ambulatory patients from a cardiology clinic with established CVD or risk factors for CVD. We collected simultaneous rPPG, PPG, BP, ECG, and other vital signs data from 143 subjects while at rest, and used this data plus demographics to train a deep learning model to predict BP. We report that facial rPPG yields a signal that is comparable to finger PPG. Pulse wave analysis (PWA)-based BP estimates on this cohort performed comparably to studies on healthier subjects, and notably, the accuracy of BP prediction in subjects with atrial fibrillation was not inferior to subjects with normal sinus rhythm. In a binary classification task, the rPPG model identified subjects with systolic BP $\geq$ 130 mm Hg with a positive predictive value of 71% (baseline prevalence 48.3%), highlighting the potential of rPPG for hypertension monitoring.
Computed Tomography (CT)-derived Cardiovascular Flow Estimation Using Physics-Informed Neural Networks Improves with Sinogram-based Training: A Simulation Study
Dept. of Bioengineering, University of California San Diego(加州大学圣地亚哥分校生物工程系);Dept. of Computer Science Engineering, University of California San Diego(加州大学圣地亚哥分校计算机科学与工程系);Dept. of Mechanical Engineering, Univ of Washington(华盛顿大学机械工程系);Depts of Mechanical Engineering and Cardiology, Univ. of Washington(华盛顿大学机械工程与心内科系);Depts. of Bioengineering, Radiology, University of California San Diego(加州大学圣地亚哥分校生物工程与放射学系)
Smartphone-Based Test and Predictive Models for Rapid, Non-Invasive, and Point-of-Care Monitoring of Ocular and Cardiovascular Complications Related to Diabetes