相位偏移远程光体积脉搏描记术用于从面部视频估计心率和血压

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Division of Electronics and Information Engineering, Jeonbuk National University(全南国立大学电子与信息工程系)

Gyutae Hwang, Sang Jun Lee

AI总结:

本文提出基于视觉的方法估计心率和血压,采用双阶段深度学习框架,利用相位偏移rPPG信号提升心率和血压估计精度。

摘要:

心血管疾病如高血压、心律失常和中风会严重威胁人类健康。心率和血压是心血管系统监测和早期诊断的重要生物信息。现有方法依赖于心电图和光体积脉搏描记术,需要接触皮肤表面。此外,基于导管和绑带的血压测量方法存在不便且适用性有限。因此,本文提出一种基于视觉的方法估计心率和血压。本文提出一个两阶段深度学习框架,包括双远程光体积脉搏描记术网络(DRP-Net)和受限血压网络(BBP-Net)。在第一阶段,DRP-Net推断出远距离光体积脉搏描记术(rPPG)信号用于指尖和面部区域,这些相位偏移的rPPG信号用于估计心率。在第二阶段,BBP-Net整合时间特征,并分析指尖和面部rPPG信号之间的相位差异以估计收缩压和舒张压值。为了提高心率估计的准确性,我们采用了基于帧插值模型的数据增强方法。此外,我们设计BBP-Net通过引入缩放的Sigmoid函数来推断血压值。我们的方法在MMSE-HR数据集上实现了心率估计的平均绝对误差(MAE)为1.78 BPM,比最近的方法减少了34.31%。心率估计的MAE为10.19 mmHg和7.09 mmHg。在V4V数据集上,心率、收缩压和舒张压的MAE分别为3.83 BPM、13.64 mmHg和9.4 mmHg。

英文摘要:

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑