AI总结:
本研究探讨了稳定扩散、流匹配和常规增强三种数据增强策略对基于深度学习的甲状腺闪烁显像分类的影响,发现流匹配方法在性能上最优,结合原始数据实现了最高的F1分数和AUC值。
摘要:
甲状腺闪烁显像对于诊断甲状腺疾病至关重要,但该领域的深度学习模型常常受限于有限且不平衡的数据集。本研究调查了三种数据增强策略,包括稳定扩散(SD)、流匹配(FM)和常规增强(CA),对增强基于深度学习的疾病分类的影响。来自九个医疗中心的2954名患者的前位甲状腺闪烁显像图像被分为四类:弥漫性甲状腺肿(DG)、结节性甲状腺肿(NG)、正常(NL)和甲状腺炎(TI)。使用CA以及各种SD和FM模型进行数据增强,创建了18种不同的场景。每个增强数据集用于训练ResNet18深度学习分类器。使用类别级和平均精确率、召回率、F1分数、AUC以及图像保真度指标(FID和KID)评估模型性能。基于FM的方法表现出顶级性能,其中原始数据集与FM(O+FM)配置实现了最高的微平均、宏平均和加权F1分数(0.78、0.77、0.78)和AUC值(0.95、0.93、0.94)。虽然O+FM+CA模型也产生了优秀且平衡的结果,但O+FM在统计上更优,表明高保真生成增强可以取代常规启发式方法。FM还生成了最逼真的图像,实现了最低的整体FID(0.66)和KID(0.83)。在SD变体中,结合图像和提示输入的SD1最为有效(宏平均F1:0.76;FID:4.17),表明医生生成的提示提供了关键的临床背景。整合FM和临床信息指导的SD增强显著改善了甲状腺闪烁显像分类,突显了先进生成模型在有限数据集上实现鲁棒训练的重要性。代码可在以下网址获取:this https URL
英文摘要:
Thyroid scintigraphy is vital for diagnosing thyroid disorders, yet deep learning (DL) models in this domain often struggle with limited, imbalanced datasets. This study investigates the impact of three data augmentation strategies including Stable Diffusion (SD), Flow Matching (FM), and Conventional Augmentation (CA), on enhancing DL-based classification of disease. Anterior thyroid scintigraphy images from 2,954 patients across nine medical centers were classified into four categories: Diffuse Goiter (DG), Nodular Goiter (NG), Normal (NL), and Thyroiditis (TI). Data augmentation was performed using CA as well as various SD and FM models, creating 18 distinct scenarios. Each augmented dataset was used to train a ResNet18 DL-classifier. Model performance was assessed using class-wise and average precision, recall, F1-score, AUC, and image fidelity metrics (FID and KID). FM-based methods demonstrated top-tier performance, with the Original dataset combined with FM (O+FM) configuration achieving the highest micro, macro, and weighted F1-scores (0.78, 0.77, 0.78) and AUC values (0.95, 0.93, 0.94). While the O+FM+CA model also yielded excellent, balanced results, O+FM was statistically superior, indicating that high-fidelity generative augmentation can supersede conventional heuristics. FM also produced the most realistic images, achieving the lowest overall FID (0.66) and KID (0.83). Among the SD variants, SD1 combining image and prompt inputs was the most effective (macro F1: 0.76; FID: 4.17), showing that physician-generated prompts provide critical clinical context. Integrating FM and clinically-informed SD augmentation substantially improves thyroid scintigraphy classification, highlighting the importance of advanced generative models for robust training on limited datasets. The code is available at: https://github.com/MaziarSabouri/Stable-Diffusion-Scintigraphy-Augmentation
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。