Thyroidiomics:一种从闪烁显像图像中分割和分类甲状腺病变的自动化流程
Thyroidiomics: An Automated Pipeline for Segmentation and Classification of Thyroid Pathologies from Scintigraphy Images
AI总结:
本研究提出Thyroidiomics自动化流程,基于ResUNet自动分割甲状腺闪烁显像图像,结合影像组学与XGBoost分类三类甲状腺病变,性能接近医生分割,可缩短评估时间并维持高诊断准确率。
摘要:
本研究的目标是开发一套自动化流程,利用甲状腺闪烁显像图像改进甲状腺疾病分类,旨在缩短评估时间并提高诊断准确率。研究收集了2643名患者的甲状腺前位闪烁显像图像,根据临床报告将其分为弥漫性甲状腺肿(DG)、多结节性甲状腺肿(MNG)和甲状腺炎(TH)三类,随后由专家完成图像分割。研究训练了ResUNet模型实现自动分割。分别从医生分割结果(场景1)和ResUNet分割结果(场景2)中提取影像组学特征,接着使用斯皮尔曼相关性去除高度相关的特征,并采用以XGBoost为核心的递归特征消除法(RFE)进行特征选择。所有模型均在留一中心交叉验证(LOCOCV)方案下训练:针对两种场景分别迭代训练9组算法实例,每次用8个中心的数据训练验证,在第9个中心的数据上测试。分割性能采用戴斯相似系数(DSC)评估,分类性能则采用精确率、召回率、F1值、准确率、受试者工作特征曲线下面积(ROC AUC)和精确率-召回率曲线下面积(PRC AUC)等指标评估。ResUNet在MNG、TH和DG三类的DSC值分别为0.84±0.03、0.71±0.06和0.86±0.02。场景1的分类准确率为0.76±0.04,ROC AUC为0.92±0.02;场景2的分类准确率为0.74±0.05,ROC AUC为0.90±0.02。该自动化流程在多个分类指标上的表现与医生分割结果相当,可在保持高诊断准确率的同时有效缩短评估时间。代码可在以下地址获取:https://github.com/ahxmeds/thyroidiomics.git。
英文摘要:
The objective of this study was to develop an automated pipeline that enhances thyroid disease classification using thyroid scintigraphy images, aiming to decrease assessment time and increase diagnostic accuracy. Anterior thyroid scintigraphy images from 2,643 patients were collected and categorized into diffuse goiter (DG), multinodal goiter (MNG), and thyroiditis (TH) based on clinical reports, and then segmented by an expert. A ResUNet model was trained to perform auto-segmentation. Radiomic features were extracted from both physician (scenario 1) and ResUNet segmentations (scenario 2), followed by omitting highly correlated features using Spearman's correlation, and feature selection using Recursive Feature Elimination (RFE) with XGBoost as the core. All models were trained under leave-one-center-out cross-validation (LOCOCV) scheme, where nine instances of algorithms were iteratively trained and validated on data from eight centers and tested on the ninth for both scenarios separately. Segmentation performance was assessed using the Dice similarity coefficient (DSC), while classification performance was assessed using metrics, such as precision, recall, F1-score, accuracy, area under the Receiver Operating Characteristic (ROC AUC), and area under the precision-recall curve (PRC AUC). ResUNet achieved DSC values of 0.84$\pm$0.03, 0.71$\pm$0.06, and 0.86$\pm$0.02 for MNG, TH, and DG, respectively. Classification in scenario 1 achieved an accuracy of 0.76$\pm$0.04 and a ROC AUC of 0.92$\pm$0.02 while in scenario 2, classification yielded an accuracy of 0.74$\pm$0.05 and a ROC AUC of 0.90$\pm$0.02. The automated pipeline demonstrated comparable performance to physician segmentations on several classification metrics across different classes, effectively reducing assessment time while maintaining high diagnostic accuracy. Code available at: https://github.com/ahxmeds/thyroidiomics.git.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。