采用临床视场(FOV)的临床前水介导超声平台用于分子靶向超声造影成像
Preclinical Water-Mediated Ultrasound Platform using Clinical FOV for Molecular Targeted Contrast-Enhanced Ultrasound
AI总结:
本研究提出一种基于临床腹部矩阵超声探头的水介导临床前超声平台,改造硅胶杯实现小鼠下半身浸没成像,验证了单次造影剂注射即可完成全身三维动态超声造影与分子成像、同时获取多病灶定量信息的可行性。
摘要:
研究背景:本方案介绍了一种用于临床前应用的全身三维动态超声造影(DCE-US)成像的超声(US)配置。该装置依托一款临床腹部矩阵超声探头,能够实现小鼠成像,突破了现有临床前系统通常无法完成全身体积成像与动态成像的局限。我们通过本方案证明了对小鼠整个下半身开展体积超声造影与分子三维成像的可行性,同时验证了单次注射造影剂团注即可同时对同一只动物体内的多个病灶进行成像的能力。\n研究方法:我们对一个内径101.6毫米、壁厚6.4毫米的硅胶杯进行改造,将其高度调整为76.2毫米,并在杯体下部开设一个尺寸为12.7毫米×15.9毫米的矩形侧窗。实验时将小鼠放置为头部与两条前腿置于杯外,身体其余部分留在杯内并浸没在水中;小鼠身体与杯壁接触的周边边缘用凡士林密封以防止漏水,杯内注入温水以维持小鼠体温。成像采用便携式临床超声系统(飞利浦EPIQ 7),搭配腹部矩阵阵列换能器(PM模式,X6-1),换能器从杯顶插入,调整位置以完整显示小鼠腹部。在注射P-选择素靶向微泡前后分别对小鼠进行成像。\n研究结果:本研究在患有两个相邻肿瘤的裸鼠中证明,市售临床矩阵换能器可用于实现全身三维动态超声造影(DCE-US)与分子超声成像,并且通过单次团注造影剂,即可从动物体内不同位置的多个病灶或器官获取独立的定性与定量信息。
英文摘要:
Background: This protocol introduces an ultrasound (US) configuration for whole-body 3D dynamic contrast-enhanced ultrasound (DCE-US) imaging in preclinical applications. The set-up relies on a clinical abdominal matrix US probe to enable mice imaging beyond current preclinical systems that are generally unable to capture whole-body volumetric and dynamic imaging. We demonstrate via this protocol the feasibility of volumetric contrast-enhanced and molecular 3D imaging in the entire lower body of mouse, as well as the capability of imaging multiple lesions in the same animal simultaneously with a single contrast bolus injection. Methods: We modified a silicone cup with a 101.6 mm inner diameter and 6.4 mm wall thickness, to a height of 76.2 mm and cut out a rectangular side window (12.7 mm x 15.9 mm) at the lower part of the cup. Mice were positioned with their head and the two front legs outside of the cup while the rest of the body remained inside the cup and submerged under water; the edges around the mouse's body in contact with the cup's wall were sealed with Vaseline to prevent water leakage, and the cup was filled with warm water to maintain the mouse's body heat. Imaging was conducted using a portable clinical ultrasound system (EPIQ 7 Philips) with an abdominal matrix-array transducer (PM mode, X6-1) inserted into the top of the cup, and positioned to visualize the entire of the mouse's abdomen. The mice were imaged before and after the injection of P-selectin-targeted microbubbles. Results: Here, in nude mice with two adjacent tumors, we demonstrate that a commercially available clinical matrix transducer can be utilized to achieve whole-body 3D DCE-US and molecular US imaging, as well as capture independent qualitative and quantitative information from several lesions or organs at different locations in the animal, through a single bolus injection.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。