本研究提出一种基于镀金硅倒金字塔阵列的中红外谐振结构,利用表面等离极化激元增强电场局域化,实现了全MIR范围内低浓度细菌的高灵敏检测,且该器件具备低成本、晶圆级制造及可重复使用等优势。

摘要:

中红外区域对于阐明微生物独特的生化特征至关重要。MIR谐振结构由于在纳米级孔径中增强了电场限制,展现出卓越的性能。然而,由于细菌的微米级尺寸,该技术在细菌传感中的应用仍然有限。本研究首次展示了一种MIR谐振结构,即具有光捕获能力的镀金微结构硅倒金字塔阵列,用于整个MIR范围内的细菌检测。倒金字塔微米级腔体内的电场局域化通过利用表面等离极化激元放大了光与物质的相互作用,从而提高了检测灵敏度。基于有限元方法的电场模拟进一步证实了电场的限制效应。特别是,我们观察到在极低浓度的细菌细胞下,大肠杆菌和金黄色葡萄球菌的定性和定量检测均得到显著增强,反映了我们检测方法的有效性。此外,这种低成本的微结构硅采用金属辅助化学蚀刻法和无光刻方法制造,并具备晶圆级制造能力。而且,我们的器件配置甚至表现出可重复使用性和可重复性,相比传统检测方案提供了实质性优势。因此,这种与CMOS技术兼容的生物传感器为将该技术与未来的生物应用集成提供了有希望的途径。

英文摘要:

The mid-infrared region is crucial for elucidating the unique biochemical signatures of microorganisms. The MIR resonant structures turned out to facilitate exceptional performance owing to the enhance electric field confinement in the nano-sized aperture. However, the extension of such technique in bacteria-sensing remains limited, primarily due to its micrometre size. This work is the first demonstration of a MIR resonant structure, the gold-coated micro-structured inverted pyramid array of silicon exhibiting light-trapping capabilities, for the bacteria detection in entire MIR range. The electric-field localization within the micro-sized cavity of inverted pyramid amplifies the light-matter interaction by harnessing surface plasmon polaritons, leading to improved detection sensitivity. The confinement of electric field is further corroborated by electric-field simulations based on finite element method. In particular, we observed notable enhancement in both the quantitative and qualitative detection of Escherichia coli and Staphylococcus aureus for the bacteria cell with very low concentration, reflecting the efficacy of our detection method. Furthermore, the cost-effective micro structured silicon is fabricated using metal-assisted chemical etching method with the lithography-free method, along with the capabilities of wafer-scale fabrication. Moreover, our device configuration even demonstrates the characteristics of reusability and reproducibility offers substantial benefits over conventional detection schemes. Consequently, this CMOS technology-compatible biosensor signifies promising ways for the integration of this technology with forthcoming bio-applications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑