Theoretical performance limitations and filter selection based on Fisher information of a computational photonic crystal spectrometer for trace-gas retrieval
As global climate change severely impacts our world, there is an increasing demand to monitor trace gases with a high spatial resolution and accuracy. At the same time, these instruments need to be compact in order have constellations for short revisit times. Here we present a new spectrometer instrument concept for trace gas detection, where photonic crystals filters replace traditional diffraction based optical elements. In this concept, 2D photonic crystal slabs with unique transmission profiles are bonded on a detector inside a regular telescope. As the instrument flies over the earth, different integrated intensities for each filter are measured for a single ground resolution element with a regular telescope. From this detector data, trace gas concentrations are retrieved. As an initial test case we focused on methane and carbon dioxide retrieval and estimated the performance of such an instrument. We derive the Cramér-Rao lower bound for trace-gas retrieval for such a spectrometer using Fisher information and compare this with the achieved performance. We furthermore set up a framework how to select photonic crystal filters based on maximizing the Fisher information carried by the filters and how to use the Cramér-Rao lower bound to find good filter sets. The retrieval performance of such an instrument is found to be between 0.4% to 0.9% for methane and 0.2% to 0.5% for carbon dioxide detection for a 300x300 m2 ground resolution element and realistic instrument parameters.
A broadband silicon photonic-integrated-circuit based RF spectrum analyzer with 10 MHz spectral resolution
U.S. Naval Research Laboratory(美国海军研究实验室);CREOL, The College of Optics and Photonics, University of Central Florida(中佛罗里达大学光学与光子学院CREOL);Sandia National Laboratories(桑迪亚国家实验室);AIM Photonics(AIM光子技术);Center for Integrated Nanotechnologies, Sandia National Laboratories(桑迪亚国家实验室集成纳米技术中心)
Information limits of photonic lantern wavefront sensing: a Fisher- and quantum-Fisher-information framework and its relation to Fourier-filtering sensitivity limits
Institut für Physik und Astronomie, Universität Potsdam(波茨坦大学物理与天文学研究所)
State Key Laboratory of Photonics and Communications, School of Information and Electronic Engineering, Shanghai Jiao Tong University(上海交通大学信息电子工程学院光子与通信国家重点实验室);School of Aeronautics and Astronautics, Sichuan University(四川大学航空航天学院);College of Information Science and Electronic Engineering, Zhejiang University(浙江大学信息与电子工程学院);Department of Engineering, University of Cambridge(剑桥大学工程系);Department of Electronics and Nanoengineering, Aalto University(阿尔托大学电子与纳米工程系)
On-chip spectrometer using stratified waveguides filters
我们提出了一个超紧凑的单次激发光谱仪在硅平台上具有宽的工作带宽和高分辨率。它由32个分层波导滤波器(SWF)与不同的传输光谱采样未知的输入信号的频谱和一个专门设计的超紧凑结构,用于分离入射信号到32个滤波器低不平衡。每个分光器的占地面积小于1um x 30um,而1x32分光器和32个滤波器总共占用约35um x 260um的面积,据我们所知,这是在硅光子平台上实现的占地面积最小的光谱仪。实验结果表明,该光谱仪具有以1550nm为中心的180nm宽工作带宽和0.45nm半高宽的窄带光谱峰。这个概念也可以使用其他材料平台来实现,用于在各种应用的感兴趣的光谱带中操作。
On-sky Demonstration of Subdiffraction-limited Astronomical Measurement Using a Photonic Lantern
University of California Los Angeles(加州大学洛杉矶分校);College of Engineering, University of Hawai'i(夏威夷大学工程学院);Institute for Astronomy, University of Hawai’i(夏威夷大学天文学研究所);California Institute of Technology(加州理工学院);Steward Observatory, University of Arizona(亚利桑那大学斯图尔德天文台);College of Optical Sciences, University of Arizona(亚利桑那大学光学科学学院);Astrobiology Center(天体生物学中心);Observatoire de Paris, Universit´e PSL, Sorbonne Universit´e, Universit´e Paris Cit´e, CY Cergy Paris Universit´e, CNRS(巴黎天文台,PSL大学,索邦大学,巴黎西岱大学,CY塞尔吉巴黎大学,法国国家科学研究中心);The College of Optics and Photonics, University of Central Florida(中佛罗里达大学光子和光学学院);Sydney Institute for Astronomy, The University of Sydney(悉尼大学悉尼天文学研究所)