40米望远镜中搭配激光导星的Shack-Hartmann与金字塔波前传感器的性能对比

Performance comparison of the Shack-Hartmann and pyramid wavefront sensors with a laser guide star for 40 m telescopes

Francisco Oyarzun, Cedric-Taissir Heritier, Vincent Chambouleyron, Thierry Fusco, Paul Rouquette, Benoit Neichel

AI总结:

针对40米级望远镜激光导星自适应光学系统,研究扩展噪声模型对比两种波前传感器性能,发现单传感器配置下金字塔波前传感器更优,层析系统中二者性能接近,搭配亚电子读出噪声探测器时性能几乎一致。

摘要:

研究背景:新一代巨型拼接镜面望远镜将在其自适应光学(AO)系统中使用激光导星(LGS)。可用作波前传感器(WFS)的两种方案分别是Shack-Hartmann波前传感器(SHWFS)和金字塔波前传感器(PWFS)。研究目的:本文对比PWFS与SHWFS的噪声性能,旨在明确两种波前传感器在单传感器配置或层析配置中哪种更具优势。研究方法:为计算噪声性能,我们将原本为PWFS开发的噪声模型扩展至可应用于SHWFS的版本。为此,我们将SHWFS的质心算法表示为矩阵-向量乘法,从而能够利用噪声统计特性计算其在AO环路中的传播过程。我们通过直径8米和16米望远镜的端到端仿真验证了该噪声模型的有效性。研究结果:对于仅配备单个波前传感器的AO系统,我们发现在子孔径数量相同的情况下,PWFS的性能优于SHWFS。对于40米望远镜,PWFS的极限星等比SHWFS高约1个星等。当使用多个波前传感器并通过广义最小二乘估计器融合信号时,我们的模型预测在层析系统中,SHWFS的性能优于PWFS,其极限星等高0.3个星等。若为PWFS配备亚电子级读出噪声(RON)探测器,则两种波前传感器的性能几乎一致。研究结论:我们认为,在搭配LGS使用单个波前传感器时,PWFS是比SHWFS更优的选择;但对于层析系统,二者的性能几乎相当。

英文摘要:

Context. The new giant segmented mirror telescopes will use laser guide stars (LGS) for their adaptive optics (AO) systems. Two options to use as wavefront sensors (WFS) are the Shack-Hartmann wavefront sensor (SHWFS) and the pyramid wavefront sensor (PWFS). Aims. In this paper, we compare the noise performance of the PWFS and the SHWFS. We aim to find which of the two WFS is the best to use in a single or tomographic configuration. Methods. To compute the noise performance we extended a noise model developed for the PWFS to be used with the SHWFS. To do this, we expressed the centroiding algorithm of the SHWFS as a matrix-vector multiplication, which allowed us to use the statistics of noise to compute its propagation through the AO loop. We validated the noise model with end-to-end simulations for telescopes of 8 and 16 m in diameter. Results. For an AO system with only one WFS, we found that, given the same number of subapertures, the PWFS outperforms the SHWFS. For a 40 m telescope, the limiting magnitude of the PWFS is around 1 magnitude higher than the SHWFS. When using multiple WFS and a Generalized least squares estimator to combine the signal, our model predicts that in a tomographic system, the SHWFS performs better than the PWFS having a limiting magnitude 0.3 magnitudes higher. If using sub-electron RON detectors for the PWFS, then the performances are almost identical between the two WFSs Conclusions. We conclude that when using a single WFS with LGS, the PWFS is a better alternative than the SH. However, for a tomographic system, either would have almost the same performance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑