一种用于测量高对比度成像中交叉偏振的实验室方法
A Laboratory Method for Measuring the Cross-Polarization in High-Contrast Imaging
AI总结:
本文提出一种利用线偏振器分离并测量恒星日冕仪中交叉偏振电场的非迭代实验室校准方法,数值模拟表明该方法能高精度估计暗坑内极微弱的交叉偏振电场,且无需增加复杂设备。
摘要:
现有的电场共轭(EFC)方法不适用于处理此处称为交叉偏振的微小偏振效应。EFC利用可变形反射镜(DM)来消除图像平面内暗坑区域中来自宿主恒星的电场,从而允许探测行星。本文提出了测量恒星日冕仪中交叉偏振电场实验室方法的实际数值模拟。这种新方法使用线偏振器来分离交叉偏振分量,并使用与现有EFC方法类似的探测程序来测量对应于交叉偏振的电场。提出的非线性探测方案专门用于解决偏振器泄漏问题。该方法并非现有EFC程序为了消除交叉偏振场而进行的推广;相反,它是一种非迭代的实验室校准程序,可用于仪器表征和数值模型验证。然而,经过实验室验证的交叉偏振数值模型可直接应用于在轨观测。提出的实验方法并不比现有的测试平台程序要求显著更高,几乎不需要额外设备。然而,模拟结果表明,该方法能够对暗坑中对应于交叉偏振的电场进行高精度估计。这些令人鼓舞的结果表明实验室实施是可行的。模拟是针对随机像差Lyot日冕仪进行的,其在图像平面中的暗坑尺寸约为 $\sim 4 \lambda/D \times 4 \lambda/D$,对比度(即行星与恒星的强度比)单位为 $\sim 10^{-10}$。该方法准确估计的交叉偏振电场对应的对比度单位强度为 $\sim 10^{-11}$。
英文摘要:
Existing Electric Field Conjugation (EFC) methods are not suited for treating small polarization effects, referred to here as cross polarization. EFC utilizes a deformable mirror (DM) to nullify the electric fields from the host star within a \emph{dark hole} region in the image plane, allowing the detection of planets. This article presents realistic numerical simulations of a laboratory method for measuring the cross-polarization electric field in a stellar coronagraph. This novel method uses linear polarizers to isolate the cross polarization component and probing procedures similar to those in existing EFC methods to measure the electric field corresponding to cross polarization. The proposed nonlinear probing scheme is specifically designed to address polarizer leakage. The method is not a generalization of existing EFC procedures in order to null the cross polarization field; rather, it is a non-iterative laboratory calibration procedure with applications in instrument characterization and validation of numerical models. However, lab-validated numerical models of the cross-polarization are directly applicable to on-sky observations. The proposed experimental method is not significantly more demanding than existing testbed procedures, requiring little additional equipment. Yet, the simulation results demonstrate highly accurate estimates of the electric field corresponding to the cross polarization in a dark hole. These encouraging results suggest that laboratory implementation is viable. Simulations are performed for a randomly aberrated Lyot coronagraph with a dark hole size of $\sim 4 λ/D \times 4 λ/D$ in the image plane with a contrast of $\sim 10^{-10}$ in contrast (i.e., the planet-to-star intensity ratio) units. The cross-polarization electric fields accurately estimated by the method correspond to intensities of $\sim 10^{-11}$ in contrast units.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。