arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2409.15546eess.IVcs.CV
收藏

一种使用大规模Vision Transformer自动表征革兰氏染色血培养玻片的新框架

A Novel Framework for the Automated Characterization of Gram-Stained Blood Culture Slides Using a Large-Scale Vision Transformer

Dartmouth College(达特茅斯学院);Geisel School of Medicine at Dartmouth(达特茅斯盖泽尔医学院);Dartmouth-Hitchcock Medical Center(达特茅斯-希契科克医疗中心);Stanford University School of Medicine(斯坦福大学医学院);Stanford Health Care(斯坦福医疗保健中心)

Jack McMahon, Naofumi Tomita, Elizabeth S. Tatishev, Adrienne A. Workman, Cristina R Costales, Niaz Banaei, Isabella W. Martin, Saeed Hassanpour

AI总结:

本研究提出了一种基于transformer的新框架用于革兰氏染色全切片图像分类,无需切片级手动标注,在475张玻片数据集上达到0.858准确率和0.952 AUC,且在外部数据集上展现出强大的泛化能力。

摘要:

本研究引入了一个新框架,用于人工智能辅助表征革兰氏染色全切片图像(WSIs)。作为血流感染诊断的测试,革兰氏染色提供关键的早期数据以指导患者治疗。快速可靠的革兰氏染色分析与更好的临床结果呈正相关,凸显了改进工具以自动化革兰氏染色分析的需求。在这项工作中,我们开发了一个基于transformer的新模型用于革兰氏染色WSI分类,它比以前基于卷积神经网络(CNN)的方法更易扩展到大型数据集,因为它不需要切片级别的手动标注。我们还引入了来自Dartmouth-Hitchcock Medical Center(美国新罕布什尔州黎巴嫩市)的大型革兰氏染色数据集来评估我们的模型,探索了五类革兰氏染色WSI的分类:成簇革兰氏阳性球菌、成对/链状革兰氏阳性球菌、革兰氏阳性杆菌、革兰氏阴性杆菌以及无细菌玻片。我们的模型在475张玻片的数据集上使用五折嵌套交叉验证,实现了0.858的分类准确率(95% CI: 0.805, 0.905)和0.952的AUC(95% CI: 0.922, 0.976),证明了大规模transformer模型用于革兰氏染色分类的潜力。我们进一步展示了我们训练模型的泛化能力,它在无需额外微调的情况下在外部数据集上取得了强劲的表现。

英文摘要:

This study introduces a new framework for the artificial intelligence-assisted characterization of Gram-stained whole-slide images (WSIs). As a test for the diagnosis of bloodstream infections, Gram stains provide critical early data to inform patient treatment. Rapid and reliable analysis of Gram stains has been shown to be positively associated with better clinical outcomes, underscoring the need for improved tools to automate Gram stain analysis. In this work, we developed a novel transformer-based model for Gram-stained WSI classification, which is more scalable to large datasets than previous convolutional neural network (CNN) -based methods as it does not require patch-level manual annotations. We also introduce a large Gram stain dataset from Dartmouth-Hitchcock Medical Center (Lebanon, New Hampshire, USA) to evaluate our model, exploring the classification of five major categories of Gram-stained WSIs: Gram-positive cocci in clusters, Gram-positive cocci in pairs/chains, Gram-positive rods, Gram-negative rods, and slides with no bacteria. Our model achieves a classification accuracy of 0.858 (95% CI: 0.805, 0.905) and an AUC of 0.952 (95% CI: 0.922, 0.976) using five-fold nested cross-validation on our 475-slide dataset, demonstrating the potential of large-scale transformer models for Gram stain classification. We further demonstrate the generalizability of our trained model, which achieves strong performance on external datasets without additional fine-tuning.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑