arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2409.09993physics.ins-detphysics.med-ph
收藏

OpenDosimeter:开源硬件个人X射线剂量仪

OpenDosimeter: Open Hardware Personal X-ray Dosimeter

Mama Lucy Kibaki Hospital(玛玛露西·基巴基医院);Stanford University(斯坦福大学);Kenya Bureau of Standards(肯尼亚标准局);University of Nairobi(内罗毕大学);NuclearPhoenix(核凤凰);Strathmore University(斯特拉瑟莫尔大学)

Norah Ger, Alice Ku, Jasmyn Lopez, N. Robert Bennett, Jia Wang, Grace Ateka, Enoch Anyenda, Matthias Rosezky, Pamela Kilavi, Adam S. Wang, Kian Shaker

AI总结:

OpenDosimeter是一种低成本开源硬件X射线剂量监测设备,利用241Am校准实现实时剂量率监测,精度±25%。

摘要:

我们介绍了OpenDosimeter(www.opendosimeter.org),这是一种基于闪烁计数器的开源硬件解决方案,用于实时个人X射线剂量监测。使用一个定制电路板上的X射线传感器组件(LYSO + SiPM)和由Raspberry Pi Pico供电,OpenDosimeter提供实时反馈(1Hz)、数据记录(10小时)和电池供电功能。其中一项核心创新是利用离子化烟雾探测器中发现的241Am进行校准。具体来说,我们使用γ射线发射进行光谱校准,然后通过补偿闪烁体吸收效率并应用从ICRP 116出版物中表格数据中得出的能量到剂量系数,计算X射线暴露的有效剂量。我们证明这种透明的方法能够在0.1-1000μSv/h之间提供实时剂量率读数,线性响应,精度±25%,测试能量最高可达120keV。最大剂量率读数受到计数率饱和的影响(约77kcps,约13μs平均脉冲处理时间)。制作OpenDosimeter的总组件成本低于100美元,结合其开源设计(硬件和软件),使全球范围内低成本的本地可复制性成为可能。通过学生研讨会,我们还展示了其作为教育和能力建设工具的有效性。本文通过开源文档补充,解释了底层技术、剂量计算算法以及未来改进的领域。

英文摘要:

We present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry Pi Pico, OpenDosimeter provides real-time feedback (1 Hz), data logging (10 hours), and battery-powered operation. One of the core innovations is that we calibrate the device using $^{241}$Am found in ionization smoke detectors. Specifically, we use the $γ$-emissions to spectrally calibrate the dosimeter, then calculate the effective dose from X-ray exposure by compensating for the scintillator absorption efficiency and applying energy-to-dose coefficients derived from tabulated data in the ICRP 116 publication. We demonstrate that this transparent approach enables real-time dose rate readings with a linear response between 0.1-1000 $μ$Sv/h at $\pm$25% accuracy, tested for energies up to 120 keV. The maximum dose rate readings are limited by pile-up effects when approaching count rate saturation ($\sim$77 kcps at $\sim$13 $μ$s average pulse processing time). The total component cost for making an OpenDosimeter is <\$100, which, combined with its open design (both hardware and software), enables cost-effective local reproducibility on a global scale. Through a student workshop, we also demonstrate its effectiveness as an educational and capacity-building tool. This paper complements the open-source documentation by explaining the underlying technology, the algorithm for dose calculation, and areas for future improvement.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑