X射线谱比释动能与环境剂量和个人剂量的转换系数
Conversion Coefficients from Kerma to Ambient Dose and Personal Dose for X-Ray Spectra
摘要:
在辐射防护中,全身照射的防护量是有效剂量$E$。有效剂量无法测量,已采用操作量进行剂量测量和剂量计及测量仪器的校准。为了克服目前使用的操作量的一些缺点,ICRU报告委员会26引入了两个新的全身照射量,环境剂量$H^*$用于前瞻性剂量评估,个人剂量$H_p(α)$用于个人剂量计的回顾性测量。剂量计和测量仪器在参考场中进行校准,用放射性同位素和明确的X射线光谱实现。本文计算了由空气比释动能$K_a$到新的环境剂量和个人剂量的谱平均转换系数,并与已发表的现行工作量的转换系数进行了比较。特别是在低能量($E_{ph}$ < 40 keV),新的数量显着低于目前的,从而纠正了严重高估的有效剂量。
英文摘要:
In radiation protection, the protection quantity for whole-body exposure is effective dose $E$. Effective dose cannot be measured and operational quantities have been introduced for dose measurement and calibration of dosimeters and survey instruments. To overcome some shortcomings of the presently used operational quantities, ICRU Report Committee 26 introduces two new quantities for whole body exposure, ambient dose $H^*$ for prospective dose assessment and personal dose $H_p(α)$ for retrospective measurements with personal dosimeters. Dosimeters and survey instruments are calibrated in reference fields, realised with radioisotopes and with well-defined x-ray spectra. In this paper, the spectrum-averaged conversion coefficients from kerma in air $K_a$ to the new quantities ambient dose and personal dose are calculated and compared with the published coefficients for the present operational quantities. Especially at low energies ($E_{ph}$ < 40 keV), the new quantities are significantly lower than the present ones, thus correcting a strong overestimate of effective dose.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。