arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2408.10828physics.ins-det
收藏

可扩展的DAQ系统,用于运行CHIPS-5中微子探测器

Scalable DAQ system operating the CHIPS-5 neutrino detector

Belén Alonso Rancurel, Son Cao, Thomas J. Carroll, Rhys Castellan, Erika Catano-Mur, John P. Cesar, João A. B. Coelho, Patrick Dills, Thomas Dodwell, Jack Edmon… 展开作者

Belén Alonso Rancurel, Son Cao, Thomas J. Carroll, Rhys Castellan, Erika Catano-Mur, John P. Cesar, João A. B. Coelho, Patrick Dills, Thomas Dodwell, Jack Edmondson, Daan van Eijk, Quinn Fetterly, Zoé Garbal, Stefano Germani, Thomas Gilpin, Anthony Giraudo, Alec Habig, Daniel Hanuska, Harry Hausner, Wilson Y. Hernandez, Anna Holin, Junting Huang, Sebastian B. Jones, Albrecht Karle, George Kileff, Kai R. Jenkins, Paul Kooijman, Arthur Kreymer, Gabe M. LaFond, Karol Lang, Jeffrey P. Lazar, Rui Li, Kexin Liu, David A. Loving, Petr Mánek, Marvin L. Marshak, Jerry R. Meier, William Miller, Jeffrey K. Nelson, Christopher Ng, Ryan J. Nichol, Vittorio Paolone, Andrew Perch, Maciej M. Pfützner, Alexander Radovic, Katherine Rawlins, Patrick Roedl, Lucas Rogers, Ibrahim Safa, Alexandre Sousa, Josh Tingey, Jennifer Thomas, Jozef Trokan-Tenorio, Patricia Vahle, Richard Wade, Christopher Wendt, Daniel Wendt, Leigh H. Whitehead, Samuel Wolcott, Tianlu Yuan

AI总结:

本文为CHIPS-5中微子探测器提出一种基于模块化阵列、可扩展且成本低廉的DAQ系统,支持30个PMT和0.69纳秒时间分辨率,并通过调试测试验证了其大规模应用可行性。

摘要:

CHIPS研发项目专注于通过新颖的设计策略和巧妙的工程技术,开发低成本水切伦科夫中微子探测器。本工作介绍了一种端到端的DAQ解决方案,用于近期的一个5千吨级CHIPS原型,该方案主要基于价格低廉的大规模生产组件。与探测器本身类似,所提出的仪器由模块化阵列组成,这些阵列可以扩展并易于维护。单个这样的阵列最多可承载30个光电倍增管(PMT),并配有现场产生高电压的电子设备,时间分辨率可达0.69纳秒。此外,该技术与White Rabbit定时系统兼容,后者可将其元件同步至100皮秒以内。尽管部署问题使得所提出的DAQ系统未能超出初始评估阶段运行,但所提出的硬件和软件成功通过了众多调试测试,证明了它们可用于配备数千个PMT的大型中微子探测器。

英文摘要:

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑