Diffusion model has been successfully applied to MRI reconstruction, including single and multi-coil acquisition of MRI data. Simultaneous multi-slice imaging (SMS), as a method for accelerating MR acquisition, can significantly reduce scanning time, but further optimization of reconstruction results is still possible. In order to optimize the reconstruction of SMS, we proposed a method to use diffusion model based on slice-GRAPPA and SPIRiT method. approach: Specifically, our method characterizes the prior distribution of SMS data by score matching and characterizes the k-space redundant prior between coils and slices based on self-consistency. With the utilization of diffusion model, we achieved better reconstruction results.The application of diffusion model can further reduce the scanning time of MRI without compromising image quality, making it more advantageous for clinical application
Introducing DEFORMISE: A deep learning framework for dementia diagnosis in the elderly using optimized MRI slice selection
International Hellenic University(国际希腊大学);MetaMind Innovations;Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Kingston University London(伦敦金斯顿大学);University of Western Macedonia(西马其顿大学)
Navigator-Free Submillimeter Diffusion Imaging using Multishot-encoded Simultaneous Multi-slice (MUSIUM)
实现亚毫米级各向同性分辨率弥散磁共振成像(dMRI)的能力对于研究精细尺度的大脑结构,特别是在皮层中至关重要。执行亚毫米dMRI的主要挑战之一是固有的低信噪比(SNR)。虽然已经提出了能够减轻高分辨率dMRI中的低SNR的方法,即同步多板(SMSlab)和具有同步多切片的广义切片抖动增强分辨率(gSlider-SMS),但是这些方法存在局限性。SMSlab序列遭受板边界伪影并且需要用于相位估计的附加导航器。另一方面,gSlider序列需要相对高的RF功率和峰值幅度,这增加了SAR并使RF激励复杂化。在这项工作中,我们开发了一个导航器的无多拍编码的同时多切片(MUSIUM)成像方法的3 T MR扫描仪,实现增强的SNR,低射频功率和峰值振幅,并从板边界伪影。dMRI的分辨率为0.86 mm各向同性分辨率,全脑覆盖,采集时间约为12.5 min,显示了皮质和白质区域的详细结构。模拟和体内结果还证明,MUSIUM成像受运动的影响最小。综上所述,MUSIUM成像是在临床可行的扫描时间内在3 T MR扫描仪上实现亚毫米扩散成像的有前途的方法。
Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T
Centre for Translational Cardiovascular Imaging, Institute of Cardiovascular Science, University College London(转化心血管成像中心,心血管科学研究所,伦敦大学学院);Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital(临床生理学,临床科学系,伦德大学,斯德哥尔摩大学医院);Department of Biomedical Engineering, Faculty of Engineering, Lund University(生物医学工程系,工程学院,伦德大学);Research & Collaborations GBI, Siemens Healthcare Ltd(研究与合作GBI,西门子医疗有限公司)
针对实时同步多层 bSSFP 心脏磁共振成像中采集和重建时间长的问题,提出基于 3D U-Net 的深度伪影抑制方法,实现快速在线重建,显著缩短采集和重建时间,同时保持诊断图像质量。
College of Health Science and Environmental Engineering, Shenzhen Technology University(深圳科技大学健康科学与环境工程学院);University Medical Center Göttingen(哥廷根大学医学中心);Guangdong-Hongkong-Macau CNS Regeneration Institute, Key Laboratory of CNS Regeneration (Jinan University)-Ministry of Education, Jinan University(广东-港澳-澳门神经科学再生研究所,神经科学再生重点实验室(暨南大学)-教育部,暨南大学);Department of Radiology, The First Hospital of Tsinghua University(清华大学第一医院放射科);Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University(清华大学生物医学成像研究中心,生物医学工程系,医学院);Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University(教育部生物医学工程重点实验室,生物医学工程与仪器科学学院,浙江大学);Department of Endocrinology and Metabolism, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine(浙江大学医学院邵逸夫医院内分泌科);Lab of Molecular Imaging and Medical Intelligence, Department of Radiology, Longgang Central Hospital of Shenzhen (Shenzhen Clinical Medical College, Guangzhou University of Chinese Medicine(分子成像与医学智能实验室,放射科,深圳龙岗中心医院(深圳临床医学院,广州中医药大学;龙岗临床学院,汕头大学医学院));Longgang Clinical Institute of Shantou University Medical College)